Mitsubishi Electric PLK - G Series Technical Manual page 29

Electronic pattern sewing machine
Table of Contents

Advertisement

< sequel to INPUT SIGNAL >
Code
Fixed angel (rotation/reverse
BC
rotation) signal
Counter clear signal
CCL
Start cancel signal
SRC
Up counter clear signal
CCU
Down counter clear signal
CCD
Up counter addition signal
UAD
Up counter subtraction signal
UDC
Down counter addition signal
DAD
Down counter subtraction
DDC
signal
Signal that invalidates MENU
KNK
key
Signal that invalidates "pattern
RNK
read" key
Signal that invalidates "pattern
WNK
write" key
Signal that invalidates
INK
"teaching input" key
Signal that invalidates
MNK
"teaching modification" key
Signal that invalidates
CNK
"teaching conversion" key
Signal that invalidates
PNK
"program mode" key
Signal that invalidates "IN/OUT
NNK
setting" key
Signal that invalidates "function
FNK
mode" key
Signal that invalidates "speed"
SNK
key
Pattern number switch signal
P01
+1
Pattern number switch signal
P02
+2
Pattern number switch signal
P04
+4
Pattern number switch signal
P08
+8
Pattern number switch signal
P16
+16
Pattern number switch signal
P32
+32
Machine head tilting detection
HES
signal
DO NOT USE
I_9
DO NOT USE
I_A
Function
To confirm the needle thrust position, the needle is stopped just before the
sewing material. Whenever BC input is ON, operation of [rotation] → [reverse
rotation] → [rotation] is repeated. When the start switch is on afterwards,
following sewing operation is started. However, if the following data is non
stitch feed, the message [M-020] is appeared, in this case please move the
needle to up position and re-turning on the start switch. Setting value of fixed
angle can be set in the [ Function mode > Needle down angle setting].
When CCL input is on, UP/DOWN counter is cleared.
When SRC input is on, sewing operation with Stringhalt is prohibited.
When CCU input is on, UP counter is cleared.
When CCD input is on, DOWN counter is cleared.
When UAD input is on, 1 is added to UP counter
When UDC input is on, 1 is subtracted from UP counter
When DAD input is on, 1 is added to DOWN counter
When DDC input is on, 1 is subtracted from DOWN counter
When KNK is on, "MENU" key becomes invalid.
When RNK is on, "pattern read" key becomes invalid.
When WNK is on, "pattern write" key becomes invalid.
When INK is on, "teaching input" key becomes invalid.
When MNK is on, "teaching modification" key becomes invalid.
When CNK is on, "teaching conversion" key becomes invalid.
When PNK is on, "program mode" key becomes invalid.
When NNK is on, "IN/OUT setting" key becomes invalid.
When FNK is on, "function mode" key becomes invalid.
When SNK is on, "speed" key becomes invalid.
When P01 is on, pattern data number is switch to 801 (800+1).
When P01 is on, pattern data number is switch to 802 (800+2).
When P01 is on, pattern data number is switch to 804 (800+4).
When P01 is on, pattern data number is switch to 808 (800+8).
When P01 is on, pattern data number is switch to 816 (800+16).
When P01 is on, pattern data number is switch to 832 (800+32).
< When you want to change to other patterned numbers >
*Pattern number can be changed within the range from 800 to 863.
*P01,P02,P04,P08,P16,P32 is effective when [Pattern select function by
external signal(APC)] has been set to ON.
When HES input is on, message [M-038] is displayed.
Specifications
ex.1) pattern number to 803
turns on P01 input and P02 input
P01 (+1) + P02 (+2) + 800 = 803
ex.1) pattern number to 811
turns on P01, P02 and P08 input
P01 (+1) + P02 (+2) + P08 (+8) + 800 = 811
[9] - 2

Advertisement

Table of Contents
loading

Table of Contents