Mitsubishi Electric PLK - G Series Technical Manual page 18

Electronic pattern sewing machine
Table of Contents

Advertisement

4.Timing chart for
[Clamp link setting (CF)]=ON, [Valid Number of clamp setting (FN)]=4
Clamp input 1
IF1
Clamp output 1
OF1
Clamp output 2
OF2
Clamp output 3
OF3
Clamp output 4
OF4
Note: Halt switch is validated.
5.Timing chart for
[Selection of pneumatic pressure two-step (AF2)]=ON
Can not use other function in "Work holder" mode.
Pneumatic pressure
two-step clamp
input signal
A2F
Start
input signal
SRT
Pneumatic pressure
two-step clamp
low pressure output AFL
Pneumatic pressure
two-step clamp
high pressure output AFH
Pneumatic pressure
two-step clamp
eject pressure output AFE
Movement of
sewing machine
ON
1A
ON
2A
ON
3A
ON
4A
ON
ON
ON
ON
ON
ON
ON
ON
ON
3B
ON
4B
ON
ON
ON
ON
ON
ON
[7] - 3
1B
2B
ON
ON
ON
1T

Advertisement