Mitsubishi Electric PLK - G Series Technical Manual page 26

Electronic pattern sewing machine
Table of Contents

Advertisement

6.Block diagram (output control section)
Physical output
O1
O2
O3
7.Explanation of operation (output control section)
The operation of the signal output from the physical output is selected and then the signal is connected to
the output port F point.
Logic operation selection
A point
When "normal"(NO) is selected, the input waveform is connected.
(1)
When "alternate"(AL) is selected, the signal will alternately turn ON and OFF, turning ON at the
(2)
first rising edge and OFF at the next rising edge.
Operation
selection
NO
AL
Alternate
OFF delay
NO
D
OFF delay
Setting time
Chopping
OF
ON
Full wave time
Duty
Full wave time
Setting value x 100µs
Input signal O1
"Normal"
A
"Alternate"
A
ON delay
OF
A
ON
C
100% ON
66% ON(8ms ON/4ms OFF)
66% ON(4ms ON/2ms OFF)
50% ON(4ms ON/4ms OFF)
50% ON(2ms ON/2ms OFF)
33% ON(2ms ON/4ms OFF)
17% ON(2ms ON/10ms OFF)
8% ON(2ms ON/22ms OFF)
Manual setting
[8] - 4
ON delay
Setting time
Logic
changeover
OF
ON
Output port
E
B
D