DANGER:
THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION AND
DEATH.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY
AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT. UNIT MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE:
The data plate is located above the control panel behind
the screen mesh. The oven voltage, wattage, serial
number, wire size, and clearance specifications are on the
data plate. This information should be carefully read and
understood before proceeding with the installation.
NOTICE:
The installation of any components such as a vent hood,
grease
conform to their applicable National, State and locally
recognized installation standards.
4.1 Electrical Connection
The oven is supplied with a cord and plug connected. The plug provided is a
NEMA-L6-20P. The receptacle is not provided with the oven. The installer should
install a NEMA-L6-20R close enough to the oven for the plug to reach the outlet.
Follow the receptacle manufacturer's instructions when connecting the receptacle
to the power supply.
4.2 Oven Voltage
The Lang Model EQS oven can be operated on 208 Volts or 240 Volt source. The
Amp draw and KW rating at both voltages are listed in the table below.
MODEL VOLT KW AMPERAGE
EQS-AP
208
EQS-AP
240
extractors,
fire
extinguisher
3.0
14.0
3.9
16.0

INSTALLATION

systems,
must
8