Problems
Causes
Excessive
The appliance is not on a
vibration.
flat, stable surface.
Volume of ingredients is too
high.
Error in assembling the
accessories.
Leak through lid.
Volume of ingredients is too
high.
The lid is not fitted
correctly.
Leak from the
Incorrect positioning of the
bowl or accesso-
seal on the blade unit
ries
(D1)(E1)(F1).
The blade unit
(D1)(E1)(F1) is
insufficiently or incorrectly
locked on the bowl
(D4)(E4)(F4).
The blade does
Pieces of food that are too
not rotate easily.
big or too hard.
Is your appliance still not working?
Contact customer service (see contact details in the booklet).
14
Solutions
Put the appliance on a flat stable surface.
Reduce the quantity of ingredients
processed.
Check that the bowls (E4) (F4) are
correctly assembled with the blade units
(E2) (F2) associated with them, the
coloured markers should be identical.
Reduce the quantity of ingredients
processed.
Check that the seal is in place (D5) on
the lid (D6). Correctly position the lid
(D6) on the bowl (D). Lock the button
(D7).
Make sure that the seal is correctly
positioned, the lips of the seal should be
visible and it should not be buckled
(fig1). Handle the blade units (D1),
(E1), (F1) with care because the blades
are sharp.
Make sure that the blade unit and the
bowl are fitted together correctly be
pressing at the top of the button
(D2)(fig2c) or on the buttons (E2)(F2)
(fig5c)
Reduce the size or quantity of the
ingredients processed.
Add liquid to the bowl mix without