INTERRUPT BAR INPUTS (TB11)
INTERRUPT BAR
WARNING (TB8)
WARNING OUT Relay contacts close depending on the programmed setting of the warning.
PHONE LINE (J9)
PHONE LINE
INS/OUTS. INT. SENSE / SHADOW SENSE/ EXIT SENSE (TB12/TB13/TB14/TB15) INPUTS
INSIDE
INTERRUPT
SENSE
OUTSIDE
INTERRUPT
SENSE
SHADOW
SENSE
EXIT
SENSE
RADIO INPUT (TB6)
RADIO RECV
MAGLOCK INPUT (TB4)
MAGLOCK
32 of 40
Gate fully open or close: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens a closing gate and starts
the Reclose Timer if timer is enabled.
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation fully opens the closing gate and starts
the Reclose Timer if timer is enabled.
Gate fully open or closed: activation prevents the gate from closing only.
Gate opening or closing: activation prevents the gate from closing. When
the interrupt loop clears, the gate begins closing.
♦ If Gate Type = Slide, gate brakes whenever it stops.
♦ If Gate Type = Swing, gate brakes only at open or close limit.
♦ If Gate Type = Barrier, gate never brakes.
Activation causes the gate to reverse for a programmable distance
and stop. If Max Retry Count is enabled, gate waits a programmable pause
time, then tries to resume. The gate will retry up to twice before faulting out.
Terminals connect the telephone line to the gate operator.
Input from an Inside Interrupt loop provides the signal for an optional
LiftMaster
loop detector add-on board. Operation is the same as the Interrupt Loop
input, above.
Input from an Outside Interrupt loop provides the signal for an optional
LiftMaster loop detector add-on board. Operation is the same as the Interrupt
Loop input above.
Input from shadow loop provides signal for optional LiftMaster loop detector
add-on board. Operation is the same as Shadow Loop input, above.
Input from exit loop provides signal for optional LiftMaster loop detector add-
on
board. Operation is the same as Exit Loop input, above.
Convenience terminals provide power (24VAC, 200mA) and signal
connection for a radio receiver. Activation is the same as Cycle.
NO and COM inputs can close a circuit (i.e., Maglock) when the Close Limit
switch is activated (the gate is fully closed).