Figure 10. Gate Sensitivity Adjustments Location - Chamberlain BG 3100-X1 Installation And Operation Instructions Manual

Barrier gate operator
Table of Contents

Advertisement

1. TYPICAL INSTALLATION ADJUSTMENTS
"Left Reverse" Adjustment (R160)
1.
Initiate opening the gate.
2.
Wait 1 to 2 seconds, then lightly "tug" against the edge of the gate to simulate an obstacle.
3.
If the gate does not stop or back up, reclose the gate and adjust the pot slightly counterclockwise.
4.
Repeat steps 1-3 until the gate stops or backs up when tugged and has the desired sensitivity.
"Right Reverse" Adjustment (R69)
1.
Open the gate fully, then initiate closing the gate.
2.
Wait 1 to 2 seconds, the lightly "bump" the leading edge of the gate to simulate an obstacle.
3.
If the gate does not stop or back up, reopen the gate and adjust the pot slightly counterclockwise.
4.
Repeat steps 1-3 until gate stops or back up when bumped and has the desired sensitivity.
2. RESTRICTED INSTALLATION ADJUSTMENTS
"Right Reverse" Adjustment (R69)
1.
Initiate opening the gate.
2.
Wait 1 to 2 seconds, then lightly "tug" against the edge of the gate to simulate an obstacle.
3.
If the gate does not stop or back up, reclose the gate and adjust the pot slightly counterclockwise.
4.
Repeat steps 1-3 until the gate stops or backs up when tugged and has the desired sensitivity.
"Left Reverse" Adjustment (R160)
1.
Open the gate fully, then initiate closing the gate.
2.
Wait 1 to 2 seconds, the lightly "bump" the leading edge of the gate to simulate an obstacle.
3.
If the gate does not stop or back up, reopen the gate and adjust the pot slightly counterclockwise.
4.
Repeat steps 1-3 until gate stops or back up when bumped and has the desired sensitivity.
3. INRUSH CURRENT ADJUSTMENT (R203)
1.
Turn the pot fully counterclockwise.
2.
Initiate opening the gate.
3.
If the gate stops due to a fault condition, slightly adjust the pot clockwise.
4.
Repeat steps 2 and 3 until the gate cycles without a fault.
5.
Open the gate fully, then initiate closing the gate.
6.
If the gate stops or back up due to a fault condition, slightly adjust the pot clockwise.
7.
Repeat steps 6 and 7 until the gate cycles without a fault and has the desired sensitivity.
12 of 40

Figure 10. Gate Sensitivity Adjustments Location.

Doc 6001343 (01-20299)
Rev B

Advertisement

Table of Contents
loading

Table of Contents