CONTROLS

KEYPAD
SWITCH S1
GATE OPEN TO Selects the direction the gate will open for typical installation (left) and
LEFT/RIGHT
SWITCH S2
POWER FAIL
(LEFT/RIGHT)

INDICATORS

LED indicators light when controls and inputs are active. Additional indicators are as follows:
DISPLAY
LEFT LIMIT
RIGHT LIMIT
MTR LEFT
MTR RIGHT
XMIT
RECV
LINE
OFF HOOK
TIMER
FAULT
MAX RUN TIME Indicates the motor ran for more than 75 second without reaching a limit switch,
REVERSE
OVERLOAD
OPEN MTR

FUNCTIONAL INPUTS

– The term "activation" means closing an input circuit (via a relay or switch), and may be
NOTES:
momentary or continuous. Momentary activations are superseded by any command.
Continuous activations are superseded only by an overriding command.
— Activating any command when gate is at the open limit stops the Reclose Timer. When
any command (except Manual Close and Stop) clears, the Reclose Timer is reset.
MANUAL INUPTS: OPEN, CLOSE, AND STOP (TB2)
MAN OPEN
30 of 40
The 12-key keypad is used for local operation, programming and service.
restricted installation (Right).
Selects the direction the Power Fail Operation option will move the gate
(Left/Right) if AC power fails.
This is a seven segment character display that gives numerical response to
service personnel during programming and operation.
Indicates that the LEFT limit switch is activated.
Indicates that the RIGHT limit switch is activated.
Indicates that the gate is moving counter clockwise.
Indicates that the gate is moving clockwise.
Indicates data is being sent to the other unit in a Master/Slave system.
Indicates data is being received from the other unit in a Master/Slave system.
Indicates the ring detect for incoming telephone call and if the phone line is
available when the gate operator wants to initiate a call.
Indicates the gate operator is off hook and using the phone line.
Indicates the Reclose Timer is running. Timer is set at pot R94.
Indicates a fault in the system. See Fault List in Part 5, Troubleshooting and
Maintenance.
and was topped. Usually requires mechanical service. See Fault List in Part 5,
Troubleshooting and Maintenance.
Indicates the peak motor current threshold was reached. See Fault List in Part 5,
Troubleshoot and Maintenance.
Indicates that the average motor current threshold was reached. See Fault List
in Part 5, Troubleshooting and Maintenance.
Indicates the motor is engaged, but is not drawing any current. The thermal
overload switch on the motor may need to be reset. See Fault List in Part 5,
Troubleshoot and Maintenance.
Activation fully opens the gate. Continuous activation holds gate open.
Man Open overrides Anti-Tailgate (ATG, Reclose Timer, and all controls but
Man Stop).
Doc 6001343 (01-20299)