Chamberlain BG 3100-X1 Installation And Operation Instructions Manual page 34

Barrier gate operator
Table of Contents

Advertisement

MAN CLOSE
MAN STOP
ENTRY SYSTEM/FIRE SWITCH INPUTS (TB9)
CYCLE
FIRE
EXIT LOOP/SHADOW LOOP DETECTOR INPUTS (TB10)
EXIT LOOP
SHADOW LOOP Activation prevents the gate from opening or closing so the gate won't hit a
INSIDE/OUTSIDE INTERRUPT LOOP DETECTOR (TB16)
INSIDE
INTERRUPT LOOP with Gate Type = Swing and ATG enabled
INSIDE
INTERRUPT LOOP with Gate Type = Swing and ATG disabled
INSIDE
INTERRUPT LOOP with Gate Type = Slide or Barrier and ATG enabled
Rev B
Activation fully closes the gate. Continuous activation holds gate closed.
Man Close overrides all controls but Man Stop, Man Open and Fire.
De-activation stops opening and closing gates. Man Stop overrides Reclose
Timer and all other controls, manual or automatic. If Man Stop is
disconnected from its COMMON, no commands affect the gate.
Reclose Timer Disabled:
Activation opens the gate, which remains open until another command is
received. A Cycle command when the gate is fully open closes the gate.
This Alternate action allows a single command to both open and close the
gate. Cycle also opens a closing gate. If Anti-Tailgating (ATG) is enabled,
Alternate Action is disabled. With ATG enabled, the gate begins closing as
soon as the Inside Interrupt Loop clears.
Reclose Timer Enabled:
Activation opens the gate, then the Reclose Timer closes the gate. A
Cycle command also opens a closing gate, but will not close a fully open gate
if the Reclose Timer is enabled. If Anti-Tailgating (ATG) is enabled, the gate
closes as soon as the Inside Interrupt Loop clears.
Activation opens the gate. Continuous activation holds the gate open. If
Reclose Timer is disabled, when Fire is deactivated, gate closes immediately.
If Reclose Timer is enabled, when Fire is deactivated, the Reclose Timer
starts. Fire overrides all commands but Manual Stop.
Same as Cycle, but does not close the gate when it is fully open.
vehicle. If the gate is already moving, or if the gate is not fully opened or
closed, this input has no effect (swing gate only).
Gate fully open or closed: activation prevents the gate from moving. When
the Interrupt loop clears, the gate begins closing.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, an opening gate closes and a closing gate resumes its course.
Gate fully open or closed: activation prevents the gate from moving.
Gate opening or closing: activation halts the gate. When the Interrupt
Loop clears, the gate resumes its course.
Gate fully open or closed: activation prevents the gate from closing. When
the Interrupt Loop clears, the gate begins closing.
Gate opening or closing: activation halts a closing gate. When the
Interrupt Loop clears, an opening gate closes and a closing gate resumes its
course.
Doc 6001343 (01-20299)
31 of 40

Advertisement

Table of Contents
loading

Table of Contents