SLAVE I/O INPUT (TB5)
SLAVE I/O

ADJUSTMENTS

REVERSE
RIGHT (R61)
REVERSE
LEFT (R160)
NOTE:
INRUSH
(R203)

CONNECTORS

LIMIT SWITCH (J4)
BATTERY I/O (J15)
PWR INPUT (J1)
MOTOR POWER (J3)
LOOP DETECTOR
(J12)
LOOP DETECTOR
(J13)
LOOP DETECTOR
(J14)
LOOP DETECTOR
(J15)
34 of 40
Input/Output terminals are used to control a second gate operator in a
Master/Slave system.
Adjustable pot controls gate sensitivity to blockages by the instantaneous
rise in motor current. When the limit exceeded, the gate reverses a
programmed distance and stops. If Max Retry Count is enabled, the gate
waits a programmed pause time, then tries to resume. The gate will retry
twice before faulting out.
Adjustable pot controls gate sensitivity to blockages by the instantaneous
rise in motor current. When the limit exceeded, the gate reverses a
programmed distance and stops. If Max Retry Count is enabled, the gate
waits a programmed pause time, then tries to resume. The gate will retry
twice before faulting out.
LiftMaster gate operators have two reverse sense adjustments (left and right)
where other gate operators have only one. This allows greater flexibility of
installation. For instance, you can install a gate on an incline and not worry
about sacrificing downhill gate sensitivity.
Adjustable pot controls the delay in sensitivity to a Reverse Sense input.
This delay in sensitivity prevents the initial motor inrush current from causing
a fault condition. The weight of the gate determines this setting.
Connector for the left/right limit switch cable.
Connector use by the Power Fail Operation unit.
Connector for AC input power.
Connector for the motor cable.
Connector for the optional LiftMaster Outside Interrupt Loop detector
add-on board.
Connector for the optional LiftMaster Inside Interrupt Loop detector
add-on board.
Connector for the optional LiftMaster Shadow Loop detector
add-on board.
Connector for the optional LiftMaster Exit Loop detector
add-on board.