WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING.
Symptom
Vacuum will not operate
Dust comes from motor cover.
Reduced efficiency and
motor/speed vibration.
TROUBLESHOOTING
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Collection tank full.
1) The reusable cloth filter is missing or
damaged.
1) There is a blockage in the nozzle,
hose, or the vacuum inlets. Or the dust
filter is blocked by fine dust.
Corrective Action
1) Check power supply – cord,
breakers, fuses.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Empty collection tank.
1) Attach or replace the reusable
cloth filter.
1) Check nozzle, hose and inlets
for blockage. Take off the filter and
clean it. Or install new filter.
11