SYSTEM OVERVIEW

Maximum System Capabilities
Control Units - 1 PC4000 Main Board
128 Zones
PC4000 Main Board: 16 zones
PC4108 Expansion Module: 8 zones
PC4116 Expansion Module: 16 zones
64 High Current Outputs - Up to 16 PC4204 Modules
144 Low Current Outputs
- 9 PC4216 16 Output Modules
1 RS-232 Interface - PC4400
16 Remote LCD Keypads - LCD-4500
1 Main Board Fully Programmable Output
1 12 VDC Switched Fully Programmable Auxiliary
Power Supply (Main Board)
1 Supervised Fully Programmable Bell / Siren Output
(Main Board)
1 Telephone Interface (Main Board)
128 Programmable Zones
16 zones on main board expandable by using 8 and
16 zone modules
Several zone types including: instant, 2 types of
interior, 3 delay, 3 fire, 4-24 hour, forced answer,
momentary, and maintained arming
Zone expansion is done by enrolling an expansion
module
Zones can be assigned independently to any
partition(s)
LCD Keypads (LCD-4500)
Total of 16 on the system
Can be assigned to any partition
209 Outputs
1 main board transistor switch to ground with 3A
capabilities (programmable for 1 of 23 options)
64 relay outputs programmable for 1 of 23 options
each (16-4204 modules with 4 outputs each)
16 switched transistor outputs programmable for 1 of
23 options each (1-4216 module with 16 outputs)
128 alarm status indicators (8-4216 modules with 16
outputs each)
Switched Auxiliary Output
Programmable for 1 of 23 options
Values shown
Supervised Alarm Output
Bell Output, 700 mA fused at 5 Amps, 12 VDC
unregulated
Steady or Pulsed Output
Programmable for 1 of 23 options
Event Buffer
512 events
Date and time stamp
8 True Partitions
Separate or shared zones from other partitions
Individual keypads per partition (minimum 1 keypad)
Individual access codes for each partition
Individual keypad zones (Fire, Emergency, Panic)
Individual outputs programmable per partition
RS-232 Interface Module (PC4400)
Used to output data to a local printer
Internal Memory
Retains programmed data even when both AC and
Battery have been removed.
The clock will have to be reset after a power down
condition which will be indicated by an audible trouble.
Keypad User Options
They are all menu driven, including:
Programming of up to 11 types of security codes, 128
in total
Bypassing from the keypad by authorized personnel
Utility functions such as remote control of lights, door
strikes, etc.
Communicator
Communicates in all 10 and 20 BPS single line and
extended formats
Radionics Rounds and Radionics Parity
Sescoa Superfast format
Ademco Contact ID format
SIA 1986 format
Surgard 4/3 DTMF format
3/1 and 4/2 formats
Hexadecimal numbers
DTMF and Pulse dialing
DPDT line seizure
True dial tone detect
Anti-jam feature
Three telephone numbers and nine account codes
Split reporting
2