DSC PC4000 System Manual page 32

Hide thumbs Also See for PC4000:
Table of Contents

Advertisement

PC4000 NEW FEATURES FOR VERSION 1.3
System Manual (Book 4)
1. Partition Mask ... Page 19
Access codes can be enabled for more than one partition.
2. "Secure System or Enter Code" ... Page 16
The message is displayed when a force armable zone is open, to indicate to the user that the partition can be
armed with the zone open.
3. Armed Light Flashes when "At-Home" Armed ... Page 21
The armed light will flash to indicate the partition has been armed in the [ ][9] At-home armed mode.
4. Keypad Trouble Indication for PC4204's ... Page 17,18
[ ][2] Troubles include PC4204 AC, Battery and Aux Supply Troubles.
5. Hardware Reset ... Page 5
The zone 1 and PGM output terminals on the main panel can be shorted to reset the panel to factory defaults.
Programming Manual (Book 3)
6. XTAL Timebase ... Page 8
An option to have the 24 hour clock timing to be internally produced rather than be taken from the 60 Hz of
the incoming 120 Volts AC.
7. FTC Audible Bell ... Page 23
A failure to communicate with the monitoring station can be annunciated by the bells sounding while a
partition is armed.
8. TLM + Alarm Bell ... Page 23
An option to have the bells sound if an alarm occurs (including silent alarms) while
trouble.
9. Ringback ... Page 23
An option to have the keypads beep to annunciate when the PC4000 has successfully communicated with the
monitoring station.
10. European Pulse Dialing ... Page 24
An option to use American pulse dialing or European pulse dialing.
11. Second Master Reporting Codes ... Page 27
The Second Grand Master Access Code now has its own opening and closing reporting codes when it is
used to arm and disarm.
12. PC4216 Zone Follower Option ... Page 30
The PC4216 can follow any group of 16 zones. When a zone is open the output is active. When the zone is
closed the output is inactive.
13. Zone Follower Option For PGM OUTPUTS ... Page 33
All Outputs (SW Aux, Main Bell, Main Panel PGM Output, PC4204 Outputs, PC4216 Custom PGM Array) can
be programmed to follow zones.
14. Zone Alarms Option For PGM OUTPUTS ... Page 33
All Outputs (SW Aux, Main Bell, Main Panel PGM Output, PC4204 Outputs, PC4216 Custom PGM Array) can
be programmed to annunciate alarms for individual zones. When a zone goes into alarm, the output will latch
active to annunciate an alarm.
15. Zone Follows + Alarms ... Page 9
An option to have all outputs programmed as zone followers to be an alarm annunciator when armed, and to
be a zone follower when disarmed.
16. Surgard 4/3 DTMF Communications Format ... Page 15,19
A 4/3 DTMF communications format for transmitting to a Surgard receiver.
17. Installer's Lockout ... Page 5
Prevents the Installer's code and the downloading access code from being reset to factory default when a
software or hardware reset occurs.
18. PC ID Restores ... Page 23
If this option is enabled the PC4000 will transmit the zone restoral reporting codes instead of the zone alarm
reporting codes for partial closing identification.
Digital Security Controls Ltd.
Toronto, Canada
Tel.: 800 387 3630 FAX: 905 760 3034
there is a telephone line

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents