Fluids for Mobile Hydraulic
Tool Circuits
The specification listed here will
provide good all season operation
if your circuit is of proper design
and normal maintenance is per-
formed.
(Periodic filter change,
draining of condensate, etc.
Recommended Fluid
The fluids listed here work well
over a wide temperature range at
start-up, allow moisture to settle
out, and resist biological growth
likely in cool-operating hydraulic
Circuits.
These fluids are recommended by
Stanley Hydraulic Tools for use in
our tools. Other fluids that meet or
exceed the specifications of these
fluids may also be used.
P/N 15596 04/98 .5M

Hydraulic Recommendations

ITEM
Viscosity (Fluid Thickness)
Viscosity (Fluid Thickness)
Viscosity (Fluid Thickness)
Pour Point (Min. for cold startup)
Viscosity Index
Demulsibility
Flash Point
Rust Inhibition
Oxidation
Pump Wear Test
BRAND
s
AMS-Oil
Chevron
Exxon
Mobil
Gulf
Shell
Sun
Texaco
Union
Mobil
Texaco
Terresole
Shell
Pennzoil
SPECIFICATIONS
U.S.A.
50 F 450 SSU Max
°
100 F 130-225 SSU
°
140 F 85 SSE Min.
°
-10 F
°
(ASTM D2220) 140 Minimum
(ASTM D1401) 30 Minutes Max.
(ASTM D92) 340 F Min.
(ASTM D665 A&B) Pass
(ASTM D943) 1000 Hours Min.
(ASTM D2882) 60 mg Max.
RECOMMENDED FLUIDS
BIODEGRADABLE
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
METRIC
10 C 95 Centistokes Max.
°
38 C 27-42 Centistokes
°
60 C 16.5 Centistokes Min.
°
23 C
°
°
DESCRIPTION
Hydraulic Fluid MN 150 SSU, 100 V.I.
AW-MV-32
"Univis" J-26
D.T.E. 13
"Harmony" AW-HVI-1 50-32
"Lo-Hydraul" 32
"Sunvis" 805 MG
"Rando" HD-AZ
"Unax" AW-WR-32
EAL 224H
BioStar 32
EnviroLogic 132
Naturelle HF-E-32
Pennzsafe Sl200

Hide quick links: