Graco Reactor E-10 Instructions-Parts List Manual page 37

Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

PROBLEM
Pressure is higher on one side
when setting pressure with func-
tion knob.
Pressures are not balanced when
running, but pressure is gener-
ated and holds on both strokes.
Fluid leak in pump packing nut
area.
Pressure doesn't hold when
stalled against gun in spray
mode.
Pressure is higher on B side
during startup of recirculation,
especially in High Recirc mode.
Resin froths and overflows tank
after refilling hot equipment.
One gauge shows half as many
pulses as the other when pumps
are cycling.
Status indicator (red LED) not lit. Motor Power switch off.
311075V
CAUSE
Pump intake valve partially
plugged.
Air in hose. Fluid is compressible. Purge air from hose.
Unequal size hoses or unequal
hose construction.
Unequal viscosities.
Restriction on one side.
Worn throat seals.
Leaking Recirc/Spray valve.
Leaking piston valve or intake
valve in displacement pump.
Leaking gun shutoff.
This is normal. Component B is
typically higher viscosity than
component A until the material is
heated during recirculation.
Agitation from pouring. Hot mate-
rial in heaters and hoses froths
when not under pressure.
Loss of pressure on downstoke.
Loss of pressure on upstoke.
Loose indicator cable.
Failed control board.
SOLUTION
Clean pump intake valve. See
page 43.
Use matching hoses, or balance
pressures before spraying.
Change temperature setting to
balance viscosities.
Change restrictor at mix point to
balance back pressure.
Clean mix module or restrictor at
mix manifold.
Clean gun check valve screens.
Replace. See pump manual.
Repair, page 42.
Repair. See pump manual.
Repair. See gun manual.
No action required.
Turn heaters off before refilling.
Leave hoses pressurized. See
page 26.
Intake valve is leaking or not clos-
ing. Clean or replace valve; see
page 43.
Piston valve is leaking or not clos-
ing. Clean or replace valve or
packings; see page 43.
Cycle Motor Power off
then on
to reset breaker.
Check that cable is connected at
J10 pins 1 (red) and 2 (black) on
control board. See page 48.
Replace board. See page 48.
Troubleshooting
,
37

Advertisement

Table of Contents
loading

Table of Contents