Flushing
7.
Set function knob to Stop/Park
8.
Wipe out any remaining material from
the supply tanks. Fill each supply tank
with 1-2 gal. (3.8-7.6 l) of solvent recom-
mended by your material manufacturer.
9.
Set function knob to Fast Recirc
Pump solvent through system to waste
containers.
10.
When nearly clear solvent comes from
recirculation tubes, set function knob to
Stop/Park
tubes to supply tanks.
11.
Set function knob to Fast Recirc
Circulate solvent through system for
10-20 minutes to ensure thorough
cleaning.
32
. Return recirculation
To flush gun, refer to gun instruction
.
manual.
Purge Gun Hoses (Nonheated
Units Only)
Disconnect hoses from gun and secure
back into the tanks for thorough clean-
ing with solvent.
Turn Recirc/Spray valve A to Spray.
.
Open gun into waste container A.
Set function knob to Slow Recirc
Set function knob to Stop/Park
Repeat for B side.
12.
Set function knob to Stop/Park
13.
Solvent flushing is a two step process.
Go back to step 4, drain solvent, and
.
flush again with fresh solvent.
14.
Leave unit filled with solvent, plasticizer,
clean motor oil, or refill supply tanks with
new material and reprime.
Never leave the unit dry unless it has
been disassembled and cleaned. If fluid
residue dries in the pumps, the ball
checks may stick the next time you use
the unit.
until hose is flushed.
.
.