8.
Fill wet-cups
Keep the felt washers in the pump
wet-cups saturated with Graco ISO
pump oil, Part No. 217374. The lubri-
cant creates a barrier between the ISO
and the atmosphere.
Pump rod and connecting rod move during
operation. Moving parts can cause serious
injury such as pinching or amputation. Keep
hands and fingers away from wet-cup during
operation. Shut off Motor Power
before filling wet-cup.
Fill wet-cups through slots
in plate, or loosen screws
and swing plate aside.
311075V
9.
Fill fluid tanks
To prevent cross-contamination of fluids and
equipment parts, never interchange compo-
nent A (isocyanate) and component B (resin)
parts or containers.
Have at least two 5 gal. (19 liter) pails to
transfer fluid from drums to supply tanks.
Label one pail "A" and the other "B", using
the red and blue labels provided. Always
doublecheck which material you have before
pouring it in the supply tanks. Pouring is eas-
ier if pails are not filled to the top.
Open only one supply tank at a time, to avoid
splashing material from one tank into the
other when filling.
Using a drill and mixing blade, mix filled or
TI6985a
separated materials in the pail before add-
ing to the tanks. Material left in the tanks
overnight may need to be remixed in the
tanks.