Raised Hearth Extension And Raised Fireplace - Vermont Castings SB100 Installation Manual

Woodburning fireplace installation and fireplace setup
Hide thumbs Also See for SB100:
Table of Contents

Advertisement

2. Raised Hearth Extension and Raised Fire-
place
Non-combustible flooring a minimum of 20 in. (508 mm)
in front of and 12 in. (305 mm) to each side of the fuel
opening is required.
The hearth framing must be constructed of non-com-
bustible materials (such as metal framing or equivalent
material) and placed on HX3(s), HX4(s) or equivalent
material. See Figure 7.8.
When creating the platform, allow for the thickness
of the non-combustible finishing materials.
Seal gaps between the hearth extension and the front
of the fireplace with a bead of non-combustible sealant
or grout.
20 in. minimum
Hearth Extension
1/2 in. Micore
or equivalent
insulation
Figure 7.8
Raised Hearth Extension and Fireplace Framing Materials
VCG Biltmore Series • SB100 • 4013-303 Installers Manual • Rev A • 02/19/15
32
Continuous,
non-combustible sealant
Tile, stone or other
non-combustible finishing
material
Protective Metal
Hearth Strips
Non-combustible
Framing Material
Note: The bottom of the fireplace
opening is 8 3/4 in. (222 mm)
above the bottom of the
fireplace. Finished hearth must
NOT extend above this level.
Platform must be built
to raise the bottom of
the fireplace opening
to the level of the
desired hearth height.
Floor and platform constructed of
wood or other combustible material

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sb100hb

Table of Contents