Locate outside air kit on one side of fireplace.
Figure 3.16 Close-up of Outside Air Kit
•
Open door (raise handle up to open, refer to Figure 2.1
for location of handles).
•
Bend the four tabs out at 90 degrees. See Figure 7.20.
Figure 3.17 Bending Tabs on Outside Air Kit Collar
VCG Biltmore Series • SB100 • 4013-303 Installers Manual • Rev A • 02/19/15
16
•
Position ring over tabs and screw in place. See
Figure 3.18.
•
Repeat for other side.
Figure 3.18 Attaching Outside Air Kit Collar
•
Check the operation by moving the outside air control
handles up and down.
•
Mark and cut out a 4-1/2 in. (114 mm) hole in the building
side for air entry.
•
Install the outside air inlet hoods in the sidewall of the
structure, flush with the building's exterior.
•
Assemble the flexible duct (not supplied) between the
collar and the outside air inlet hood. Secure into position
with the supplied wire ties.
•
Check for light leaks with a flashlight and seal with duct
tape and/or insulation.