2
Getting Started
A. Typical Fireplace System
Additional lateral
support for chimney
above roof (or enclosed
in chase) if needed
Non-combustible
roof flashing maintains
minimum clearance
around chimney
Support straps
on rafter support
chimney
Ceiling firestop
on floor of attic
Chimney system
Combustible framing/header
on top of V-shaped standoffs
Outside
combustion air
Figure 2.1
Typical Fireplace System
VCG Biltmore Series • SB100 • 4013-303 Installers Manual • Rev A • 02/19/15
Protective metal
hearth strip(s)
Termination cap
Storm Collar
Chimney penetrates roof
preferably without affecting
roof rafters
Offset & Return (with hanger straps)
Attic insulation shield
must be used here to keep
insulation away from chimney
if attic is insulated
Framing headed off
in ceiling joists
Enclosed space above
and around fireplace
Mantel and surround
Decorative facing
and trim
Hearth extension
Factory-built fireplace
5