Motorola WT4070 Integrator Manual page 186

Wearable terminal
Hide thumbs Also See for WT4070:
Table of Contents

Advertisement

A - 8
WT4070/90 Wearable Terminal Integrator Guide
RS507 Technical Specifications (Continued)
Table A-4
Item
Supported Symbologies
Supported Aiming Modes Class 2 Laser, cross hair with bright center for sunlight visibility; Pick List mode
Interface
Field Replaceable Parts
User Interface
LED
Beeper
Restore Key
Scan Triggering
User Environment
Operating Temperature
Storage Temperature
Humidity
Drop Specification
1D enabled by default:
Codabar, Code 39, Code 128, EAN-13, EAN-8, Interleaved 2 of 5, UPC-A and
UPC-E.
Additionally supported by 1D:
Code 11, Code 32 Pharmaceutical (PARAF), Code 93, MSI, Reduced Space
Symbology (RSS-14, RSS Limited, RSS Expanded), Straight 2 of 5 IATA (two-bar
start/stop), Straight 2 of 5 Industrial (three-bar start/stop), Trioptic, UPC-E1.
2D enabled by default:
4-CB (4-State Customer Bar code), Aztec, MicroPDF417, PDF417, MaxiCode.
Additionally supported by 2D:
Australian Post, British Post (4 state code and "infomail"), Data Matrix, Japanese
Post, KIX (Netherlands) Post, Planet Code, Postnet, QR Code, EAN/UCC
Composite, TCIF Linked Code 39 (TLC39).
option.
Cordless:
Bluetooth: Class II, v 2.1 with Adaptive Frequency Hopping (AFH).
Supported profiles: Serial Port Profile (SPP), Human Interface Device Profile (HID),
Service Discovery Application Profile (SDAP).
Pairing: by reading terminal BT address as bar code off the display or from a printed
label.
Corded (to WT4090): Serial.
Batteries, corded adaptor, trigger clamp, triggerless clamp, comfort pad, straps and
strap buckle.
Two (parallel), multi color, rear left and rear right.
Rear center, up to 80 dBA SPL @ 10 cm.
User accessible for emergency boot up and Bluetooth reconnect (after excessive
disconnection period).
Manual or automatic using Interactive Sensing Technology (IST).
-20 °C to 55 °C (-4 °F to 131 °F)
-40° to 70° C (-40° to 158° F) excluding battery
-40° to 60° C (-40° to 140° F) including battery
5% to 85% non condensing
1.8 m (6 ft.) multiple drops to concrete across operating temperature range.
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt4090

Table of Contents