Sending The Hex Image Using Ipl; Wt4070/90 - Motorola WT4070 Integrator Manual

Wearable terminal
Hide thumbs Also See for WT4070:
Table of Contents

Advertisement

Sending the Hex Image Using IPL

Once the hex file is built, it can be downloaded to the wearable terminal using IPL.
NOTE The wearable terminal must be inserted in the cradle with appropriate power supply connected to a power
source, for the wearable terminal to reset into IPL.

WT4070/90

Press the
,
1.
1
9
The screen blanks and three brackets display "} } }". Immediately press the
2.
menu displays.
Initial Program Loader
Platform
Application
Config Block
Windows CE
Monitor
Splash Screen
Power Micro
Partition Table
Command File
System Reset
Auto Select
Initial Program Loader (IPL) Menu
Figure 7-9
CAUTION
NOTE The hex images must be downloaded in the following order:
1. Monitor (wearable terminal resets after downloading monitor)
2. Config Block
3. Partition Table and Power Micro
4. Platform, Splash Screen, Application and Windows CE.
If the platform or application partition sizes are changed, you must download a new partition table first.
Choose Auto Select or use the up and down scroll buttons to select the partition to download, then press
3.
Enter.
and Power button. The wearable terminal performs a cold boot.
To insure a successful download, do not remove power from the wearable terminal while in IPL mode.
Application Deployment 7 - 11
key. The
P2
Initial Program Loader

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wt4090

Table of Contents