Main
Sub
code
code
07
08
Shifting with warm-up display
Used to measure the warm-up time.
When this simulation is executed, the following warm-up window is displayed.
The time required for starting the warm-up and completing the initializing operation and shifting to the stand-
by state is displayed.
* Though [CA] key is pressed, the machine does not enter the aging mode of intermission 0 sec.
(Warming up window)
Sim7-8 W-UP C-MODE
WARMING UP.
Press [CA] key to exit the simulation mode.
(The aging function is omitted from SIM 07-01.)
08
01
Developing bias output
Used to check the developing bias output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the developing bias signal is turned ON for 30sec. When
measuring the actual output value, however, use SIM 25-01.
After completion of the process, the machine returns to the sub code input window.
(Execution start window)
Sim8-1
DV BIAS
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts output operation and shifts to the sib code input window.
02
Main charger output (Grid = HIGH)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage HIGH
mode.
After completion of the process, the machine returns to the sub code input window.
(Execution start window)
Sim8-2
MHV(H)
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts output operation and shifts to the sub code input window.
03
Main charger output (Grid = LOW)
Used to check the main charger output.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the main charger is turned on for 30 sec in the grid voltage LOW
mode.
After completion of the process, the machine returns to the sub code input window.
(Execution start window)
Sim8-3
MHV(L)
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts output operation and shifts to the sub code input window.
Contents
(Warming up completion window)
Sim7-8 W-UP C-MODE
WARM UP COMPLETED.
1
(Execution window)
Sim8-1
OK/START Key
(Execution window)
Sim8-2
OK/START Key
(Execution window)
Sim8-3
OK/START Key
AR-M207 M165 M162 SIMULATIONS 7-10
10
DV BIAS
EXEC
MHV(H)
EXEC
MHV(L)
EXEC
Remark