Self Print; Key Reception Time Setting Display/Non-Display Setting; Info Lamp Setting - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
64
01

Self print

Used to perform printing of one page disregarding the optical system status. Also when the print command
is issued from the host, printing is performed.
When this simulation is executed, warm-up is performed and the ready lamp is lighted. (Since, however, the
optical system is invalid, initializing is not performed.)
There are following four self-printable patterns.Use 10-key to select a pattern.
The selected pattern is displayed on 7-segment LED.
7SEG LED
0
1
2
3
(4 - 99: Input invalid)
(*1) After outputting 1 line black data, white data of 2 line is outputted.
(*2) The grid pattern of about 1cm square is outputted.
(*3) Data are always made for A3 size. If printing is made on paper smaller than A3, the remaining data are
not outputted. (Images are not formed on the drum.)
(Initial window)
Ready to copy.
S
100%
8 1/2 11
1
7SEG LED
65
10

Key reception time setting display/non-display setting

Used to set Enable/Disable of the key reception time setting in the key operator program. When this setting
is set to Enable (1), the key reception time is displayed in the key operator program, allowing setting.
Sim65-10 KEY TIME
1:KEY ACK TIME
[
0- 1]
[CA] key: Exit the simulation mode.
[Interruption] key: Shifts to the sub code input window.
11

Info lamp setting

Used to set the Info lamp brightness (PWM duty) and the kind of flashing.
Sim65-11 INFO LAMP
1:PWM DUTY
2:BLINK TYPE
[
1- 5]
During this simulation, Info lamp is lighted to allow checking of the brightness.
[CA] key: Exit the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Print pattern
1BY2 mode (*1)
Grid pattern (*2)
White paper
Black background
Copies in progress.
Press OK Key or
START Key
100%
8 1/2 11
After completion of printing one sheet
Display: Setting
0: Disable
1
1: Enable (Default)
1
Lamp brightness
1: 100% (Default)
1
2: 80%
1
3: 60%
4: 40%
1
5: 20%
Kind of flashing
1: Flashing (Default)
2: Flashing 10 times, and lighting thereafter.
3: Lighting
AR-M207 M165 M162 SIMULATIONS 7-49
Contents
S
Remark
Default:
1 (Enable)
Default:
1 (Flashing)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m165Ar-m162

Table of Contents