Duplex Motor Rpm Adjustment; Duplex Motor Switchback Time Adjustment; Toner Motor Operation; Trouble Cancel (Except For U2) - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
09
04

Duplex motor RPM adjustment

Used to adjust the duplex motor rotation speed.
When this simulation is executed, the following setting window is displayed. Enter an input value with 10-key
and press [OK] key or [START] key.
The setting range is in 1-13 steps and the default is "4" (646.9PPS).
(Setting window)
Sim9-4 MOTOR SPEED
1:MOTOR SPEED
[
When a value outside the setting range is inputted, it is ignored.
[CA] key: Exits the simulation mode.
[Interruption] key: Shift to the sub code input window.
05

Duplex motor switchback time adjustment

Used to adjust the duplex motor switchback time when the motor reverse rotation is controlled.
When this simulation is executed, the following setting window is displayed. Enter an input value with 10-key
and press [OK] key or [START] key.
The setting range is 50-76, and the default is 50.
When the adjustment value is increased by 1, the distance up to reverse start is increased by 3 steps in 1-2
phase excitement.
Sim9-5 SW BACK TIME
1:SW BACK TIME
[ 50-76]
When a value outside the setting range is inputted, it is ignored.
[CA] key: Exits the simulation mode.
[Interruption] key: Shift to the sub code input window.
10
-

Toner motor operation

Used to check the operation of the toner motor.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key, and the toner motor is rotated for about 30sec.
After completion of the process, the machine shifts to the sub code input window.
(Execution start window)
Sim10 TONER MOTOR
PRESS OK KEY EXEC
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
14
-

Trouble cancel (except for U2)

* Used to cancel EEPROM writing troubles such as H trouble and execute the hard reset.
When this simulation is executed, the following execution start window is displayed. Press [OK] key or
[START] key to clear the trouble other than U2.
(Execution start window)
Sim14 TROUBLE CLEAR
TROUBLE CLEAR
(WITHOUT U2)
AER YOU SURE? EXEC
Set value : Speed (PPS)
01
: 637.2PPS(Slow)
4
02
: 640.4PPS
03
: 643.6PPS
04
: 646.9PPS(Default)
1-13]
4
05
: 650.1PPS
06
: 653.3PPS
07
: 656.5PPS
08
: 659.8PPS
09
: 662.9PPS
10
: 666.2PPS
11
: 669.4PPS
12
: 672.6PPS
13
: 675.8PPS(Fast)
50
50
(Execution window)
OK/START Key
AR-M207 M165 M162 SIMULATIONS 7-12
Contents
Sim10 TONER MOTOR
EXEC
Remark
Default:
4(646.9PPS)