Fusing Temperature Setting (Normal Copy); Standby Mode Fusing Fan Rotation Setting; Fusing Paper Interval Control Allow/Inhibit Setting - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
43
01

Fusing temperature setting (Normal copy)

Used to set the fusing temperature in normal copy.
When this simulation is executed, the current set value is displayed.
Every time when [
temperature.
Every time when [
temperature. Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is
caved in the EEPROM.
Setting can be made in the range of 160°C to 200°C in the increment of 5°C.
Sim43-1 FUSER TEMP.
1:FUSER TEMP
[160- 200]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
12

Standby mode fusing fan rotation setting

When this simulation is executed, the currently set code number is displayed.
Select a mode to be changed with the cross key and enter a set value with 10-key.
Enter the mode number to be selected with 10-key and press [OK] key or [START] key. The set value is
saved in the EEPROM.
Sim43-12 FAN SPEED
1:LOW
2:HIGH
[ 0-1]
Setting mode
LOW
Setting in normal temperature adjustment (190°C or below) Default = 0 (Low speed rotation)
HIGH
When the fusing temperature is 190°C or above,Default = 1 (High speed rotation)
13

Fusing paper interval control allow/inhibit setting

Used to change the paper feed timing of 21st sheet or later to A3 or WLT (depending on the destination
setting) when in multi copy/print of narrow width sheets.
When this simulation is executed, the current set number is displayed. Enter a code number and press
[START] key. The entered number is saved in the EEPROM and the machine returns to the sub code input
window.
Sim43-13 PICK INTVL
1:PICK INTVL
[ 0-1]
<Applicable paper>
1) Cassette paper feed: A4R,B5R,8-1/2"x14",8-1/2"x13",8-1/2"x11",A5,INV
2) Manual paper feed: A4R,B5R,8-1/2"x14",8-1/2"x13",8-1/2"x11",A5,INV,16KRÅ
* A5 is applicable to manual paper fed only in EX Japan AB series.
Contents
] key is pressed, the set value is increased by 5°C from the current display
] key is pressed, the set value is decreased by 5°C from the current display
0 : 160 C
1 : 165 C
170
2 : 170 C (Default)
3 : 175 C
4 : 180 C
170
5 : 185 C
6 : 190 C
7 : 195 C
8 : 200 C
FAN rotation speed
0 : Low speed rotation
0
1 : High speed rotation
1
0
Code: Setting
0: Disable (Default)
0
1: Enable
0
AR-M207 M165 M162 SIMULATIONS 7-27
Remark
Default:
2(170°C)
Default:
LOW:0(Low speed
rotation)
HIGH:1(High speed
rotation)
Default:
0 (Disadble)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m165Ar-m162

Table of Contents