43
01
Fusing temperature setting (Normal copy)
Used to set the fusing temperature in normal copy.
When this simulation is executed, the current set value is displayed.
Every time when [
temperature.
Every time when [
temperature. Enter a desired set value (temperature), and press [OK] key or [START] key. The set value is
caved in the EEPROM.
Setting can be made in the range of 160°C to 200°C in the increment of 5°C.
Sim43-1 FUSER TEMP.
1:FUSER TEMP
[160- 200]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
12
Standby mode fusing fan rotation setting
When this simulation is executed, the currently set code number is displayed.
Select a mode to be changed with the cross key and enter a set value with 10-key.
Enter the mode number to be selected with 10-key and press [OK] key or [START] key. The set value is
saved in the EEPROM.
Sim43-12 FAN SPEED
1:LOW
2:HIGH
[ 0-1]
Setting mode
LOW
Setting in normal temperature adjustment (190°C or below) Default = 0 (Low speed rotation)
HIGH
When the fusing temperature is 190°C or above,Default = 1 (High speed rotation)
13
Fusing paper interval control allow/inhibit setting
Used to change the paper feed timing of 21st sheet or later to A3 or WLT (depending on the destination
setting) when in multi copy/print of narrow width sheets.
When this simulation is executed, the current set number is displayed. Enter a code number and press
[START] key. The entered number is saved in the EEPROM and the machine returns to the sub code input
window.
Sim43-13 PICK INTVL
1:PICK INTVL
[ 0-1]
<Applicable paper>
1) Cassette paper feed: A4R,B5R,8-1/2"x14",8-1/2"x13",8-1/2"x11",A5,INV
2) Manual paper feed: A4R,B5R,8-1/2"x14",8-1/2"x13",8-1/2"x11",A5,INV,16KRÅ
* A5 is applicable to manual paper fed only in EX Japan AB series.
Contents
] key is pressed, the set value is increased by 5°C from the current display
] key is pressed, the set value is decreased by 5°C from the current display
0 : 160 C
1 : 165 C
170
2 : 170 C (Default)
3 : 175 C
4 : 180 C
170
5 : 185 C
6 : 190 C
7 : 195 C
8 : 200 C
FAN rotation speed
0 : Low speed rotation
0
1 : High speed rotation
1
0
Code: Setting
0: Disable (Default)
0
1: Enable
0
AR-M207 M165 M162 SIMULATIONS 7-27
Remark
Default:
2(170°C)
Default:
LOW:0(Low speed
rotation)
HIGH:1(High speed
rotation)
Default:
0 (Disadble)