Main Cassette Semicircular Roller Cleaning; Warm-Up Display And Aging With Jam; Intermittent Aging - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
06
10

Main cassette semicircular roller cleaning

Before execution of this simulation, remove the developing cartridges. When this simulation is executed, the
load select menu is displayed as shown below. Select a roller cassette to be cleaned with the 10-key. When
[OK] key or [START] key is pressed, the semi-circular roller of the specified cassette is rotated halfway round
and stopped with the roller facing downward.
(Load selection window)
Sim6-10 ROLLER CLN
1:TRAY1
2:TRAY2
3:TRAY3
EXEC
When [Interruption] key is pressed after cleaning, the machine returns to the sub code input window and the
semi-circular roller returns to the original position.
* When TRAY2 - TRAY4 are not installed, they are not displayed.
* When another cassette roller is cleaned continuously, press [Interruption] key to return the roller to the
original position and restart the simulation.
* When the simulation mode is terminated by pressing [CA] key, the roller returns to the original position by
the initializing operation.
07
01

Warm-up display and aging with jam

Used to measure the warm-up time and execute aging with jam.
When this simulation is executed, the following warm-up window is displayed.
The time required for starting the warm-up and completing the initializing operation and shifting to the stand-
by state is displayed.
After completion of warm-up, press [CA] key to exit the simulation mode, allowing normal copy operations.
The copy mode at that time is the aging mode with 0sec of intermittent aging.
(Warming up window)
Sim7-1 W-UP C-MODE
WARMING UP.
Canceled by turning off the power or executing a simulation which makes the hardware reset. When the
interruption is pressed to shift to the input standby window, the machine does not enter the aging mode.
06

Intermittent aging

Used to execute intermittent aging of 3sec. The set quantity and the mode are optionally selected.
When this simulation is executed, the following execution start window is displayed.
When [OK] key or [START] key is pressed, the machine exits the simulation mode.
Enter a desired coy mode and a desired copy quantity.
Press [START] key, and intermittent aging will be started.
(Execution start window)
Sim7-6 INTERVAL SET
AGING INTERVAL
AER YOU SURE? EXEC
It is canceled by turning off the power or executing a simulation with the hard reset.
Sim6-10 ROLLER CLN
10Key
4:TRAY4
1:TRAY1
2:TRAY2
3:TRAY3
0
1/2
(Warming up completion window)
Sim7-1 W-UP C-MODE
WARM UP COMPLETED.
1
(Copy window)
AR-M207 M165 M162 SIMULATIONS 7-9
Contents
(Execution window)
OK/START
4:TRAY4
Key
EXEC
2
(Copy window)
CA
10
Ready to copy.
S
100%
8 1/2 11
Sim6-10 ROLLER CLN
1:TRAY1
4:TRAY4
2:TRAY2
3:TRAY3
EXEC
2
Ready to copy.
S
100%
8 1/2 11
Remark

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m165Ar-m162

Table of Contents