4) Removing the fan & generator V-belt
(1) Set the tool on the pulley set bolt of the belt tensioner, rotate the belt tensioner counterclockwise to
loosen the tension and remove the fan & generator V-belt.
CAUTION:
As the pulley set bolt uses a left-threaded screw, rotating clockwise loosens the pulley set bolt.
V-belt
PERIODIC MAINTENANCE SERVICES
PM-27
PM-00592