1.136 INVALID ANGLE SENSOR #1 MODEL

Flash Code: 8-4
Invalid angle sensor #1 model. The tower angle sensor #1 (Right) is sending 10 bits of data instead of 11 bits of data. The
sensor must be replaced.
Note Pretest Instructions
1.136.1 Read fault log.
1.136.2 Plug the right tower boom
angle sensor connector
[X099] into the tower angle
sensor #2 and the left tower
boom angle sensor connec-
tor [X100] into tower angle
sensor #1

1.137 INVALID ANGLE SENSOR #2 MODEL

Flash Code: 8-4
Invalid angle sensor #2 model. The tower angle sensor #2 (Left) is sending 10 bits of data instead of 11 bits of data. The
sensor must be replaced.
Note Pretest Instructions
1.137.1 Read fault log.
1.137.2 Plug the left tower boom
angle sensor connector
[X100] into the tower angle
sensor #1 and the right
tower boom angle sensor
connector [X099] into tower
angle sensor #2

1.138 JIB DOWN OPEN CIRCUIT

Flash Code: 3-4
Jib down open circuit. The jib down output [X169.26] is open. See 1.377 COMMON STB OR OC PROCEDURE on Pg. 174.

1.139 JIB DOWN SHORT TO BATTERY

Flash Code: 3-4
Jib down short to battery. The jib down output [X169.26] is shorted to battery. See 1.377 COMMON STB OR OC PROCE-
DURE on Pg. 174.

1.140 JIB DOWN SHORT TO GROUND

Flash Code: 3-4
Jib down short to ground. The jib down output [X169.26] is shorted to ground. See 1.378 COMMON STG PROCEDURE on
Pg. 175.

1.141 JIB LEFT OPEN CIRCUIT

Flash Code: 3-4
Jib left open circuit. The jib swing left output [X169.28] is open. See 1.377 COMMON STB OR OC PROCEDURE on Pg. 174.
3128411
SECTION 1 - FAULT DICTIONARY AND SELECTED TROUBLESHOOTING
Test
Is INVALID ANGLE SENSOR #2 MODEL in
log?
Is the message INVALID ANGLE SENSOR #2
MODEL gone and the message INVALID
ANGLE SENSOR #2 MODEL in the fault
stack?
Test
Is INVALID ANGLE SENSOR #1 MODEL in
log?
Is the message INVALID ANGLE SENSOR #1
MODEL gone and the message INVALID
ANGLE SENSOR #2 MODEL in the fault
stack?
1250AJP
Result
Corrective Action
Yes
Replace both sensors.
No
Go to step 1.136.2
Yes
Replace sensor #1
No
Reprogram/replace BLAM
Result
Corrective Action
Yes
Replace both sensors.
No
Go to step 1.137.2
Yes
Replace sensor #2
No
Reprogram/replace BLAM