SECTION 4 - JLG ANALYZER
Submenu
Parameter
(Displayed on
(Displayed on Analyzer 2nd
Analyzer 1st
Line)
ACCEL X.Xs
DECEL X.Xs
MIN UP XX%
MAX UP XXX%
MIN DOWN XX%
MAX DOWN XXX%
JIB SWING:
ACCEL X.Xs
DECEL X.Xs
MIN LEFT XX%
MAX LEFT XXX%
MIN RIGHT XX%
MAX RIGHT XXX%
GROUND MODE:
m. LIFT UP XXX%
m. lift DN XXX%
SWING XXX%
BASKET LVL XXX%
BASKET ROT XXX%
MAIN TELE XXX%
TOWER TELE XXX%
T. LIFT UP XXX%
T. LIFT DN XXX%
JIB (U/D) XXX%
JIB (L/R) XXX%
GEN SET/WELDER:
Engine XXXX RPM
4-280
Table 4-2. Machine Personality Settings and Speeds
Line)
Displays/adjusts jib lift acceleration
Displays/adjusts jib lift deceleration
Displays/adjusts minimum jib up speed.
Same as Creep speed
Displays/adjusts maximum jib up speed
Displays/adjusts minimum jib down
speed. Same as Creep speed
Displays/adjusts maximum jib down
speed
Displays/adjusts jib swing acceleration
Displays/adjusts jib swing deceleration
Displays/adjusts minimum jib left speed.
Same as Creep speed
Displays/adjusts maximum jib left speed
Displays/adjusts minimum jib right speed.
Same as Creep speed
Displays/adjusts maximum jib right speed 0 to 100%
Displays/adjusts fixed main lift up speed
Displays/adjusts main lift down speed
Displays/adjusts fixed swing speed
Displays/adjusts fixed basket level speed
Displays/adjusts fixed basket rotate speed 0 to 100%
Displays/adjusts fixed main telescope
speed
Displays/adjusts fixed tower telescope
speed
Not displayed if TOWER TELE=NO
Displays/adjusts fixed tower lift up speed
Not displayed if TOWER LIFT=NO
Displays/adjusts fixed tower lift down
speed
Not displayed if TOWER LIFT=NO
Displays/adjusts jib lift speed
Not displayed if JIB = 0
Displays/adjusts jib swing speed
Displayed if JIB = 2
Control generator/welder RPM. Not dis-
played if GEN SET/WELDER = 0
Description
0.1 to 5.0 sec
0.1 to 3.0 sec
0 to 65%
0 to 100%
0 to 65%
0 to 100%
0.1 to 5.0 sec
0.1 to 3.0 sec
0 to 65%
0 to 100%
0 to 65%
0 to 100%
0 to 100%
0 to 65%
0 to 100%
0 to 100%
40 to 40%
40 to 40%
40 to 40%
0 to 100%
0 to 100%
1200-2800
1250AJP
TIME RANGE
(SEC) (SEE 4.6
DEFAULT
Range
VALUES
When Setting
1.5
1.0
40
65
30-36
40
60
30-36
1.5
0.5
40
70
42-47 (125°)
40
70
42-47 (125°)
60
60
45
75
75
65
40
40
40
60
70
1800