Limit Switch States - JLG 1250AJP Troubleshooting Manual

Hide thumbs Also See for 1250AJP:
Table of Contents

Advertisement

Limit Switch States

Connector
Switch
X051
Main Boom Transport Angle Prox
X052
Dual Capacity 1
X053
Dual Capacity 2
X054
Main Boom Transport Length 1
X055
Main Boom Transport Length 2
X056
Tower Boom Transport Length
X079
Main Lift Pilot Pressure
X146
Jib Stow
X147
Jib Center
X204
RF Axle Extension
X205
LF Axle Extension
X213
Osc Axle Lockout Pressure
X216
Drive Orientation
X225
LR Axle Extension
X226
RR Axle Extension
3128411
SECTION 2. ELECTRICAL REFERENCE
Table 2-1. Limit Switch States
Normally Open or
Closed
1-4 NC, 2-3 NO
2-3 Closed = Transport
NC
See Table 2-3. Switch States / Boom Length Regions on Pg. 179
NC
See Table 2-3. Switch States / Boom Length Regions on Pg. 179
NC
See Table 2-3. Switch States / Boom Length Regions on Pg. 179
NC
See Table 2-3. Switch States / Boom Length Regions on Pg. 179
21-22 NC, 13-14 NO
21-22 Closed = Transport
NO
Closed = Pressure > 200psi
NC
Open = Stowed (Jib > 70° Right)
NC
Open = Jib Centered ±5°
NC
Closed = Extended
NC
Closed = Extended
NO
Closed = Pressure > 200psi
NO
Open = Normal Orientation
NC
Closed = Extended
NC
Closed = Extended
1250AJP
SECTION 2 - ELECTRICAL REFERENCE
Reference State
2-177