Control Module Power - JLG 1250AJP Troubleshooting Manual

Hide thumbs Also See for 1250AJP:
Table of Contents

Advertisement

INTRODUCTION
A.6 CONTROL MODULE POWER
Always make sure that all of the control models are properly powered. See Figure A-3. Basic Electronic Module Connections
on Pg. 6
1. For Ground Module operation, Terminals [X001.24], and [X008.2] should have a voltage of Vbatt. Terminal [X008.1]
should be grounded.
2. CAN communication wires should have 60Ω resistance between CAN HI and CAN LO whenever both the Platform
Module and Chassis Module are connected or 120Ω when one of them are disconnected. Both CAN HI and CAN LO
should be isolated (show very high resistance or overload, OL) from the shield and ground. A CAN termination 120Ω
resistor is located at both ends of the CAN bus. One is embedded in the platform module. The other terminator is jum-
pered in the chassis module.
X044
J
K
X042
E
X045
J K
E
1
2
3
12
16
12 16
1 2 3
X043
X270
X269
C B A A
B
C
C B A
X014
X091
Analyzer
CAN HI
CAN LO
CAN Shield
Vbatt from EMS
Platform Mode Select
Main Angle #1 Power
Main Angle #2 Power
Vbatt from Power
Down Relay
Ground from B-
Platform Ground
Platform Power
Note: BLAM and Chassis Module Analyzer connections for download only
A-6
X048
X049
Main
Main
Boom
Boom
Angle #1
Angle #2
1 2 3 4
5
1 2 3 4
5
X050
1
2
3
12
16
BLAM Module
X086
X058
CAN HI
10
J1
6
11
CAN LO
7
12
CAN Shield
8
Ignition Power
5
4
X090
Analyzer Power
J5
9
Analyzer RS232 Receive
10
Analyzer RS232 Transmit
11
Analyzer Ground
12
Ground Module
X001
X007
Ground to Engine Module X240.1
8
J7
J1
13
Tower Lift PVG Power
3
24
18
Analyzer Power
28
Analyzer RS232 Receive
29
3
Analyzer RS232 Transmit
30
Analyzer Ground
31
14
Constant Battery (Vbatt)
24
X002
Tower Tele PVG Power
10
8
J2
21
Main Lift PVG Power
11
X097
X008
J8
2
1
3
Battery +
Battery -
4
CAN HI
CAN LO
Figure A-3. Basic Electronic Module Connections
Mode Select from Ground Module X007.14
X160
1
2
3
12
16
Vbatt from Ground Module X008.4
Ground from Ground Module X008.3
X089
J4
1
2
CAN HI
3
CAN LO
4
CAN Shield
5
1 2 3 4
1 2 3 4
X066 X067 X065 X062
Tower
Tele
Tower
PVG
Lift PVG
Chassis Power
Relay
87
X266
86
30
85
X013
Analyzer
2 1
X263
X267
X058
3
Ignition Power
2
Constant Battery (Vbatt)
X235
Analyzer
1250AJP
X169
Platform
J7
Module
Vbatt from EMS
1
X166
2
J2
32
X171
26
CAN HI
31
28
Analyzer
29
120Ω
27
CAN LO
30
X170
2
J8
1
Ignition Power
Ground from Ground Module X001.8
X262
X268
A
A
B
B
C
C
1 2 3 4 5
X060
X084
C
B
A
1 2 3 4
A B D E
Load Pin
Main Lift
PVG
X083
5
4
3
2
1
X216
5
4
3
2
1
Chassis
X229
Module
J1
CAN HI
6
120Ω
CAN LO
7
CAN Shield
8
Chassis Power
5
9
CAN Jumper
10
Ground
4
X233
Analyzer Power
9
J5
Analyzer RS232 Receive
10
Analyzer RS232 Transmit
11
Analyzer Ground
12
Engine
Module
X240
14
1
12
13
3128411

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents