SECTION 1 - FAULT DICTIONARY AND SELECTED TROUBLESHOOTING
1.127 HEAD TAIL LIGHT SHORT TO GROUND
Flash Code: 3-3
Head tail light short to ground. The head and tail light output [X002.26] is shorted to ground. See 1.378 COMMON STG
PROCEDURE on Pg. 175.
1.128 HIGH ENGINE TEMP
Flash Code: 4-3
High engine temperature. This fault should only occur on machines configured with non-ECM engines. The engine tempera-
ture is above 130°C.
1.129 HIGH RESOLUTION A2D FAILURE-INTERRUPT LOST
Flash Code: 9-9
High resolution analog to digital failure-interrupt lost. This fault should only occur with software versions prior to 7.0. There is
an internal problem with the platform module.
1.130 HIGH RESOLUTION A2D FAILURE-REINIT LIMIT
Flash Code: 9-9
High resolution analog to digital failure - reinit limit. This fault should only occur with software versions prior to 7.0. There is
an internal problem with the platform module.
1.131 HORN OPEN CIRCUIT
Flash Code: 3-3
Horn open circuit. The ground module horn output [X002.2] is open. See 1.377 COMMON STB OR OC PROCEDURE on
Pg. 174.
1.132 HORN SHORT TO BATTERY
Flash Code: 3-3
Horn short to battery. The ground module horn output [X002.2] is shorted to battery. See 1.377 COMMON STB OR OC
PROCEDURE on Pg. 174.
1.133 HORN SHORT TO GROUND
Flash Code: 3-3
Horn short to ground. The ground module horn output [X002.2] is shorted to ground. See 1.378 COMMON STG PROCE-
DURE on Pg. 175.
1.134 HOUR METER SHORT TO BATTERY
Flash Code: 3-3
Hour meter short to battery. The hourmeter output [X004.12] is shorted to battery. See 1.377 COMMON STB OR OC PRO-
CEDURE on Pg. 174.
1.135 HOUR METER SHORT TO GROUND
Flash Code: 3-3
Hour meter short to ground. The hourmeter output [X004.12] is shorted to ground. See 1.378 COMMON STG PROCEDURE
on Pg. 175.
1-90
1250AJP