JLG 1250AJP Troubleshooting Manual page 275

Hide thumbs Also See for 1250AJP:
Table of Contents

Advertisement

Configuration Digit
FUNCTION CUTOUT:
14*
* Only visible under certain market selections.
* Certain market selections will limit function cutout options or alter default setting.
GROUND ALARM:
15*
* Certain market selections will alter default setting.
OSCILLATING AXLE:
16
TEMPERATURE:
17*
* Certain market selections will alter default setting.
3128411
Table 4-1. Machine Configuration Programming Information
Number
0
NO: No drive cutout.
1
BOOM CUTOUT: Boom function cutout while driving above elevation.
2
DRIVE CUTOUT: Drive cutout above elevation.
3
DRIVE CUT E&T: Drive cutout above elevation and tilted.
0
NO: No ground alarm installed.
1
DRIVE: Travel alarm sounds when the drive function is active (Option).
2
DESCENT: Descent alarm sounds when lift down is active (Option).
3
MOTION: Motion alarm sounds when any function is active (Option).
0
NO: No oscillating axle system installed.
1
YES: Oscillating axle system installed.
0
CELSIUS: Celsius unit selection.
1
FAHRENHEIT: Fahrenheit unit selection.
Description
1250AJP
SECTION 4 - JLG ANALYZER
Default
Number
0
0
1
1
4150364-15
4-275

Hide quick links:

Advertisement

Table of Contents
loading