Safety Devices - Rinnai Energysavers RHFE-309FT Operation And Installation Manual

Hide thumbs Also See for Energysavers RHFE-309FT:
Table of Contents

Advertisement

About your Energysaver
Features
Push button ignition
Child lock function
Preheat
Economy mode
Override
Dual timer
Filter indicator
Humidifier tray

Safety devices

Overheat switch
Fusible link
Flame failure device
Electrical fuse
Power failure
Rinnai New Zealand
Only one-touch is required to turn the heater on and off.
Prevents children from altering settings when the heater is in use or activating
the heater when turned off.
This function will automatically operate the appliance before the programmed
start time in order to preheat the room.
Energy saving feature designed to control the room temperature and prevent
the room from overheating.
Temporarily changes the heater operation from on to off, or vice versa, until the
next programmed setting is reached.
Allows you to program the appliance to come on for two separate periods each
day, one in the morning and one in the evening. The dual timer feature means
you can "set and forget" your heater.
When the air (fan) filter becomes covered with dust the filter indicator will flash
indicating that cleaning is necessary.
Raise humidity in the room for extra comfort with the humidifier tray—can be
filled with water as required.
This device automatically cuts the gas off if the heater exceeds a certain
temperature. This is normally caused by an obstruction in front of the louvres,
or a blocked fan filter. If this switch operates, turn the unit off, remove
obstruction (clean filters) and let the unit cool before restarting.
Back up to the overheat switch. If a fusible link cuts off the gas a service call is
required to repair the appliance and replace the link.
If the flame goes out during operation, this device cuts off the unit (lockout). To
reset, turn the unit off, then on again. If this happens repeatedly a service call
is required.
The electrical circuits are protected by an electric fuse. When the fuse blows,
the heater will not operate. A service call is required as the fuse needs to be
replaced.
In the event of a power failure or power cut, the gas valves will automatically
close. After the power is reinstated the appliance will automatically restart. The
time of day will need to be reset to the current time.