LOCK AND SAFETY DEVICES

USING THE LOCK FUNCTION

The Lock function will avoid accidental operation and
prevent small children from altering the heater settings.
To Activate the Lock
To activate the Lock function press both the Up and
Down buttons
simultaneously. The function is
13
activated immediately and the Lock indicator
illuminated.
To Deactivate the Lock
To deactivate the Lock function press both the Up and
Down buttons
simultaneously for 3 seconds. The
13
Lock indicator
will go out to show that the Lock
29
function is no longer active. The Lock function can be
deactivated at any time in this manner.
If the Lock function is activated whilst the heater is in operation or in Timer mode, all
controls other than the ability to switch the appliance OFF with the ON/Off button
NOTE
or for models with a remote control the OFF button
deactivated. Timer operation will not be affected.
If the lock function is activated whilst the appliance is in the off position, all controls
will be locked until the Lock function is de-activated.
If the appliance is switched off whilst the Lock function is activated, all controls will
be locked until the Lock function is de-activated.
Lock programming (activated or de-activated) is stored in the appliance memory.
Unplugging the appliance from the power supply has no effect on Lock programming.

SAFETY DEVICES

Over heat switch
When the heater gets too hot during operation (for example when the filters or air outlet louvres are
blocked) this device turns the gas off automatically.
Electrical fuse
The electrical circuits are protected by a fuse.
Flame failure sensor
This device automatically cuts off the gas supply to the heater in the event of a gas failure.
Oxygen depletion sensor
If the oxygen level in the room drops below a pre-set limit, this device cuts the gas supply to the heater.
Tilt switch
If the heater is knocked over, the tilt switch will cut the gas supply. The fan keeps cycling.
Power failure
In the event of a power failure or power cut, the gas valves will automatically close.