Error code messages

The Energysaver
has built-in technology to continually monitor its own performance. If a fault
®
occurs, an error message will flash on the digital display on the control panel. This assists with
diagnosing the fault and may enable you to overcome a problem without a service call.
Code Displayed
Probable Cause
11
Ignition failure
12
Flame failure
14
Overheat
16
Room overheat
31
Room temperature sensor faulty
32
33
Overheat temperature sensor faulty
34
53
Sparker failure
61
Combustion fan failure
62
Convection fan failure
70
Faulty On/OFF switch
71
Faulty solenoids
72
Faulty flame rod
73
Communication error
In all cases, you may be able to clear the error message by turning the heater off then on
again. If the error message remains or returns when the heater is used again, contact Rinnai
or a Rinnai Service Centre.
Faults caused by an insufficient gas supply, gas quality, installation or operation errors are not
covered by the Rinnai warranty.
Rinnai New Zealand
Suggested Solution
Check gas supply is turned on, turn heater off then
on again. If ignition failure continues, a service call
will be required.
As above.
Clean filter, service call if repeated.
Lower room temperature to less than 40 °C.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Energysaver