Safety Devices - Rinnai Granada 252 Operation & Installation Manual

Portable radiant/convection gas space heater
Table of Contents

Advertisement

The guard on this appliance conforms to A.G.A. requirements. It is designed to prevent the risk
of fire or injury from burns, and no part of it should be permanently removed.
WARNING
IT DOES NOT GIVE FULL PROTECTION TO YOUNG CHILDREN OR THE INFIRM.

SAFETY DEVICES

Oxygen Depletion Sensor
This system turns the heater off if the oxygen level in the room falls below a pre-set level. This can be caused by
lack of ventilation, or using the heater in a room which is too small. Before relighting, ventilate the room, then follow
the ignition procedure. Annual cleaning is recommended, this should be carried out by Rinnai or our agent.
Flame Failure Sensing System
If the flame goes out during operation, the flame failure device automatically cuts off the gas supply to the heater.
To restore the gas supply, turn the heater off, wait 30 seconds, then follow the ignition instructions.
Tilt Switch
If the heater is knocked over, the tilt switch will cut off the gas supply. To restore the supply, stand the heater up and
follow the ignition procedure. The tilt switch may also operate if the heater is jolted or picked up while in operation.
When the tilt switch cut-off function stops operation, make sure you replace the appliance back into its correct