Horizontal rooftop installation
16
(cont.)
4. Align the mounting rails with the
tube holders and secure to the
mounting bracket.
Note
Tube holders must be aligned later-
ally to the opposite rail.
5. Screw the mounting bracket to the
other side of the mounting rail.
6. Secure the locking profile at the
bottom of the mounting rails.
7. If a second collector is fitted above
the first, fit a spacer.
Proceed as per points 2 to 5.