The wiring on two speed motors is ar-
ranged so that the motor switch directs
power to the normal speed winding and
the start winding to start the motor.
When the motor reaches switching
speed, the switches move opening the
circuit to the start winding and at the
same time transferring the power from
the normal speed winding to the slow
speed winding.
Motor and Switch Operation:
The polarity of the magnetic field of the
start winding, in relation to the magnetic
field of the run winding, determines the
direction ofthe rotation of the motor.
The timer is used to reverse the polarity
of the start winding field and the opera-
tion of the motor start switch.
(See the
line drawings as illustrated on page 7-5.)
16007667
SECTION 7. ELECTRICAL COMPONENTS AND TESTING
7-4
©
1996 Maytag Corporation