The pump assembly is located on the
right rear corner of the washer base.
The pump pulley is engaged to the drive
belt at all times and will be operating in
both motor directions: Clockwise during
agitation and counterclockwise during
spin. However, the pump is designed so
it will only discharge water from the
machine when it is running in the coun-
terclockwise, or spin direction.
REMOVAL:
1. Disconnect the unit from the power
source.
2. Remove the drain hose from the
pump outlet.
3. Remove the rear access panel from
the cabinet rear.
4. Disconnect the pump inlet hose.
5. Remove the three (3) screws which
mount the pump assembly to the
base.
6. Slide the pump forward to dis-
engage the belt from the pulley.
NOTE: If
this is done carefully, the belt
will remain on the motor and transmis-
sion drive pulley, making installation
easier.
REINSTALLING:
Place one hand through the pump open-
ing and lift belt. Set the pump pulley into
the opening and place the belt on the
pulley. While holding tension on the belt
to keep it on the pulleys, install the
mounting screws.
DISASSEMBLY:
1. Remove the pump from the washer
base.
2. Remove the four (4) screws that
secure the housing to the pump
base, and lift off the housing.
3. Remove the screw that secures the
impeller.
4. Using two (2) screwdrivers, one on
each side ofthe impeller, carefully
pry the impeller off the spline shaft.
5. Work the seal mating ring and "0"
ring up and off the shaft.
16007667
SECTION 4. WATER RELATED COMPONENTS
4·7
©
1996 Maytag Corporation