Maytag Jenn-Air Service Manual page 15

Hide thumbs Also See for Jenn-Air:
Table of Contents

Advertisement

Remove
Cardboard
Protector
Remove Hex
Head Screws
Shipping
Base
Control
Panel
washers are pushed in tightly. Attach the
hose end with the flat washer to the water
mixing valve. Hot and cold connections are
identified by H & C stamped in the cabinet.
Tighten hose connections by hand until
snug. Then, turn another 2/3 of an inch,
with pliers.
Water
:::1Htttm~~~1
Connections
Cold Water
Inlet
Water
~oses
-~
Proceed as follows:
• Place the washer as close to its
final operating location as possible.
The front legs are threaded and can
be adjusted up and down to level
the unit.
These models are equipped with
self-adjusting legs on the rear which
will automatically stabilize the unit.
Stabilizer Model
Hot Water
Inlet
6. Move washing machine to the loca-
tion where it will be used. A mini-
mum of 1/4" clearance on all sides
ofthe washer is recommended.
7. LEVELING AND/OR STABILIZING THE
WASHER
4. Install the drain hose by placing the
clamp over the hose (clamp provided
in parts envelope). Push the hose
onto the pump outlet of the washer.
Be sure to position the hose in the
direction of the standpipe. Squeeze
the clamp ears with pliers, push the
clamp up the hose and attach to
the pump outlet.
Pump
Clamp Hose
~
Cit
~_"-""--:
5. Place a flat rubber washer on one end
of the water hose, making sure the
16007667
• Make sure rear feet move up and
down freely.
SECTION 1. INSTALLATION
1-3
©
1996 Maytag Corporation

Advertisement

Table of Contents
loading

Table of Contents