Blower Installation - Quadra-Fire 31M-ACC-MBK Owner's Manual

3100 series automatic combustion control (acc) installation and operation
Hide thumbs Also See for 31M-ACC-MBK:
Table of Contents

Advertisement

R
C. Blower (Optional)
1. Remove the 3 bolts (1/4"-20 Phillips head) on the outer
skin at the bottom rear of appliance.
2. Align holes in mounting flange of blower with bolt holes in
appliance. Blower should be positioned at bottom of rear
outer skin as shown in Figure 15.1.
3. Re-insert and tighten bolts, securing blower onto outer
wall of appliance.
4. Place the bracket containing the snap disc and magnet
under the bottom left rear corner as shown in Figure 15.1.
See page 30 for detailed operating instructions for the
blower and snap disc.
Figure 15.1
Figure 15.2 - Blower Housing Dimensions
July 7, 2011
Do not remove.
Secure blower
with 3 bolts
Snap Disc
Bracket
with Magnet
Secure wires
with wire tie
13-15/16 in. (355mm)
7033-277I
3100 Wood Stove Series (ACC)
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
MANUAL: Over-rides the
Snap Disc
MANUAL
FAN
AUTO
AUTO: Fan will turn ON/OFF
Automatically by the Snap Disc
LOW
HIGH
OFF
Controls the Fan Speed
4-13/16 in.
(122mm)
CAUTION
3-1/8 in.
(80mm)
4-15/16 in.
(125mm)
Page 15