Chimney Termination Requirements; 2-10-03 Rule - Quadra-Fire 31M-ACC-MBK Owner's Manual

3100 series automatic combustion control (acc) installation and operation
Hide thumbs Also See for 31M-ACC-MBK:
Table of Contents

Advertisement

R
D. Chimney Termination Requirements
Follow manufacturers instructions for clearance, securing,
flashing and terminating the chimney.
Must have an approved and listed cap
Must not be located where it will become plugged by
snow or other material
• Must terminate at least 3 feet (91cm) above the roof
and at least 2 feet (61cm) above any portion of the
roof within 10 feet (305cm).
• Must be located away from trees or other struc-
tures
E. 2-10-3 Rule
These are safety requirements and are not meant to assure proper flue draft.
3 ft. (91cm)
Minimum
Figure 19.1
Wall or Parapet
Figure 19.2
July 7, 2011
2 ft. (61cm)
10 ft. (305cm) To Nearest Roofline
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Flat Roof
NOTE:
• Chimney performance may vary.
• Trees, buildings, roof lines and wind conditions affect
performance.
• Chimney height may need adjustment if smoking or
overdraft occurs.
Less than 10 ft. (305cm)
2 ft. (61cm)
Pitched Roof
3 ft. (91cm) Minimum
7033-277I
3100 Wood Stove Series (ACC)
3 ft. (91cm)
Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)Minimum
Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

31st-acc

Table of Contents