Error Logger Menu - Sony SRW-5000 Maintenance Manual

Hd digital
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

3-2-3. ERROR LOGGER Menu

The ERROR LOGGER menu detects error(s) occurring in
a defective system of the unit, and displays the list of the
logged error and warning messages.
This menu is also used for the settings, such as a time
setting.
For details about error and warning messages, refer to
Section 2.
To display the ERROR LOGGER menu, press the [F2]
(ERROR LOG) key on the MAINTENANCE INFORMA-
TION menu.
PAGE
ERROR LOG
F1
TOP
PAGE
96.00:15:20:29 (C) 0B
F2
END
VIDEO DATA ERROR
97.00:15:20:29 (C) 0F
FULL
AUDIO DATA ERROR
F3
MSG
98.00:15:21:02 (W) 10
VITC NOT READ
ALL
99.00:15:21:08 (W) 10
CLEAR
F4
VITC NOT READ
WARNI-
ERROR
CONDI-
DIAG
NG
TION
on
on
ALT
F5
F6
F7
[F1] (PAGE TOP) Key
Moves the cursor to the top page.
[F2] (PAGE END) Key
Moves the cursor to the page where the last message exists.
[F3] (FULL MSG) Key
Displays a message (on which the cursor is placed) in the
full message.
[F4] (ALL CLEAR) Key
Deletes the saved messages (LOG DATA).
[F5] (WARNING) Key
Selects whether to display warning messages.
on (factory setting)/off
[F6] (ERROR) Key
Selects whether to display error messages.
on (factory setting)/off
[F7] (CONDITION) Key
Selects whether to display condition messages.
on (factory setting)/off
3-4
'03/10/28
18:44:39
TOTAL 99
TIME
EXIT
on
TC
F8
F9
F10
[F9] (TIME) Key
Switches the display between time code and real time.
TC (factory setting)/REAL
[F10] (EXIT) Key
Exits the ERROR LOGGER menu and returns to the
MAINTENANCE INFORMATION menu.
ALT + [F8] (CANCEL EDIT) Key
Cancels the display of a selected warning message.
ALT + [F9] (REAL TIME) Key
Sets a date and time.
[F4] (ALL CLEAR) Key
Deletes the saved messages (LOG DATA).
Execution Procedure
1. On the ERROR LOGGER menu, press the [F4] (ALL
CLEAR) key.
PAGE
ERROR LOG
F1
TOP
! CONFIRMATION of CLEARING:
PAGE
01.00:15:20:29 (C) OB
F2
END
VIDEO DATA ERROR
02.00:15:20:29 (C) OF
FULL
AUDIO DATA ERROR
F3
MSG
03.00:15:21:02 (W) 10
Press [SFT]+[F4] to CLEAR.
VITC NOT READ
Press only [F4] to CANCEL.
ALL
04.00:15:21:08 (W) 10
CLEAR
F4
VIDEO DATA ERROR
WARNI-
ERROR
CONDI-
DIAG
NG
TION
on
on
ALT
F5
F6
F7
2. Press the [F4] (ALL CLEAR) key while pressing the
[SFT] (SHIFT) key. Then the saved messages (LOG
DATA) are deleted.
To cancel the execution, press the [F4] (ALL
CLEAR) key only.
'03/10/28
18:46:49
TOTAL 99
REALLY?
TIME
EXIT
on
TC
F8
F9
F10
SRW-5000/5500