When installing and operating your Harman Accentra
Pellet Stove, respect basic safety standards. Read these in-
structions carefully before you attempt to install or operate
the Accentra. Failure to do so may result in damage to prop-
erty or personal injury and may void the product warranty.
Consult with your local building code agency and insur-
ance representative before you begin your installation to en-
sure compliance with local codes, including the need for per-
mits and follow-up inspections.
Several issues must be addressed when selecting a suit-
able location for your Accentra Pellet Stove. Observing re-
quired clearances to combustible materials, the proximity to a
safe chimney or venting system, and the accessibility of elec-
trical supply must all be considered. In addition, selecting a
location that takes advantage of the building's natural air flow
is also desirable to maximize the heating effectiveness of the
heater. In many cases, this is a central location within the
building.
Adequate combustion and ventilation air must be pro-
vided. The Accentra pellet stove is capable of being installed
with a 100% outside air combustion system. See Page 14
about venting.
Place the stove on a noncombustible floor surface. If
the floor surface is made of a combustible material, (such as
carpet, vinyl or wood), a noncombustible material must be
installed between the bottom of the unit and the floor. This
can be a minimum of a 20 gauge sheetmetal plate, ceramic
tile with grouted joints, a UL listed stove board, or a Harman
1
Cast Iron floor protector
equal to the minimum dimensions, which are 24
lows for a 2" extension on each side of the unit and a 6"
extension to the front of the ash opening (3
from the base plate front edge.) The rear edge of the floor
protection can be flush with the cast base plate rear edge.
Place the stove away from combustible walls at least
as far as shown in figures 10, 11, 12, & 13
Note that the clearances shown are minimum for safety
but do not leave much room for access when cleaning or
servicing. Please take this into account when placing the
stove.
AFTER THE INSTALLATION IS COMPLETED
Before the first fire is lit, check and record the high
and low draft reading numbers on page 12. Make
adjustments to the low draft at this time, if necessary.
CAUTION
The stove is hot while in operation.
Keep children, clothing and furniture away.
Contact may cause skin burns.
. The Harman Cast Iron Floor Protector is
1
/
x 28
16
3
2
/
"
4
Installation
5
1.
/
This al-
8
if measured
1. Check your local codes to see if protection is required under the
flue pipe.
2. This measurement equals 6" from inside edge of ash door
opening.)
3. 5" clearance to wall in a corner installation top flue.
6.25"
2.25"
2"
FLOOR
6"
PROTECTOR
5
28
/
"*
8
(*Harman Cast Iron Floor Protector size)
This is the minimum size Harman recommends
for the alcove with a 60" ceiling.
14.75"
2.25"
54"
3
5"min.
6.25"
Fig.10
12"
Fig.11
0"
2"
Fig.12
14.75"
Fig. 13