Harman Stove Company Accentra Owner's Manual page 11

Cast iron pellet stove
Table of Contents

Advertisement

When installing the Accentra in a mobile home sev-
eral requirements must be followed:
1. The unit must be bolted to the floor. This can be
done with 1/4" lag screws throught the 2 holes in
the base plate shown in Fig. 16
2. The unit must also be connected for the outside
air. See page 14.
3. Floor protection and clearances must be followed
as shown on page 9.
CAUTION: This appliance must be vented to
the outside.
Due to high temperatures, the Accentra should be
placed out of traffic and away from furniture and draper-
ies.
Children and adults should be alerted to the hazards
of high surface temperatures and should stay away to
avoid burn to skin and/or clothing.
Young children should be carefully supervised when
they are in the same room as the stove.
Clothing and other flammable materials should not
be placed on or near the Accentra Pellet Stove.
Installation and repair of the Accentra Pellet Stove
should be done by a qualified service person. The appli-
ance should be inspected before use and at least annually
by a qualified service person. More frequent cleaning will
be required. It is imperative that control compartments,
burners, and circulating air passageways of the Accentra
be kept clean.
AFTER THE INSTALLATION IS COMPLETED
Before the first fire is lit, check and record the
high and low draft reading numbers on page 12. Make
adjustments to the low draft at this time, if necessary.
MOBILE HOME INSTALLATION
Fig. 16
Unit bolt down holes for mobile home installation lag
to floor with 1/4" lag bolts with washer (supplied by
installer.)
Mobile home installation should be done in
accordance with the Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
CAUTION
THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
CAUTION
The stove is hot while in operation.
Keep children, clothing and furniture away.
Contact may cause skin burns.
WARNING
Keep combustible materials such as grass, leaves, etc. at
least 3 feet away from the point directly under the vent
termination.