Harman Stove Company Accentra Owner's Manual

Harman Stove Company Accentra Owner's Manual

Cast iron pellet stove

Advertisement

Accentra Cast Iron
Pellet Stove Owners Manual
FOR USE IN THE U.S. AND CANADA
SUITABLE FOR INSTALLATION IN MOBILE HOMES
Contact local building or fire officials about restrictions and installation
inspection requirements in your area.
Contact your local authority (such as municipal building department, fire
R2
department, fire prevention bureau, etc.) to determine the need for a permit.

Advertisement

Table of Contents
loading

Summary of Contents for Harman Stove Company Accentra

  • Page 1 Accentra Cast Iron Pellet Stove Owners Manual FOR USE IN THE U.S. AND CANADA SUITABLE FOR INSTALLATION IN MOBILE HOMES Contact local building or fire officials about restrictions and installation inspection requirements in your area. Contact your local authority (such as municipal building department, fire...
  • Page 2: Table Of Contents

    Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. SUITABLE FOR MOBILE HOME INSTALLATIONS. SAVE THESE INSTRUCTIONS Harman Stove Company 352 Mountain House Road Halifax, PA 17032 sales@harmanstoves.com...
  • Page 3 This unit is equipped with several different The Accentra has an input heat range from safety devices which will be explained later in this 0 to 40,000 BTU's. manual. The Advance feed system has a maximum With its specially designed burn pot and feed rate of 5 lbs.
  • Page 4: Automatic Operation

    The automatic system will allow the fire size to be adjusted to match the heating needs and even put the fire out if necessary. If heat is needed after the fire is out, the Accentra will automatically re-ignite and adjust the fire size to match the heating need. The totally automatic room sensor mode is recommended because of its efficiency.
  • Page 5 AUTOMATIC START UP Starting First Fire Ignitor Switch to"AUTO" (down position) Make sure the unit is plugged into a 120 See Note 7. Fig. 3 VAC, 60 HZ electrical source. The power light 1" should be the only light lit. 1.
  • Page 6: Manual Operation

    MANUAL IGNITION/OPERATION The Accentra Pellet Stove is capable of manual operation. This also allows the operator to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, or when using certain generators.) The unit can be switched between "AUTO" and "MANUAL" at any time during operation.
  • Page 7 MANUAL START UP Starting First Fire Fig. 8 Ignitor Switch to"MANUAL" (up position) Make sure the unit is plugged into a Fig. 7 120 VAC, 60 HZ electrical source. The See Note 7. power light should be the only light lit. 1"...
  • Page 8: Esp Control

    ESP CONTROL Mode Selector Temp dial Allows you to choose between Room Temp Mode, Allows you to adjust the room temperature in Room Temp Stove Temp Mode, or OFF. Also allows you to vary the Mode using the outer scale marked in degrees Fahrenheit. distribution blower speed by turning the knob to the It also allows you to adjust the stove temperature while in high or low side of each mode.
  • Page 9: Assembly & Installation

    5"min. structions carefully before you attempt to install or operate the Accentra. Failure to do so may result in damage to prop- erty or personal injury and may void the product warranty. Consult with your local building code agency and insur-...
  • Page 10 Skid bolt down holes/floor lag down holes Adjustment of the rubber pad leveling feet The Accentra is provided with 4 rubber pad feet. These Fig. 15 feet will raise the bottom edge of the cast base plate off the floor surface. This will insure that any vibrations caused by motors and other moving parts will not be transferred by direct contact.
  • Page 11 MOBILE HOME INSTALLATION Fig. 16 When installing the Accentra in a mobile home sev- eral requirements must be followed: 1. The unit must be bolted to the floor. This can be done with 1/4" lag screws throught the 2 holes in the base plate shown in Fig.
  • Page 12 To record the results firebox tightness, gasket leakage, motor operation and ignitor for future reference: operation. The Accentra is then factory set at a high 1. Plug unit into a 120VAC, 60 HZ outlet. adjustment. NOTE: Low draft adjustment may be 2.
  • Page 13 NOTE: Distances of more than 25 feet from the unit or in another room are not recommended. The room REMINDERS sensor is essential for the Accentra's excellent efficiency. It is recommended that the room sensor be Hopper Lid installed, even if only installed on the rear of the unit as Foam Gaskets a return air sensor.
  • Page 14: Venting

    + = Positive static pressure in some cases a perfect seal is not achieved. For this = Negative static pressure reason and the fact that the Accentra operates with a positive vent pressure, we specify that the joints also be sealed with clear silicone.
  • Page 15 Venting #1 Preferred method This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall. Two and a half inches from the wall is safe; however, three inches allows better access to remove the rear panel.
  • Page 16 Venting #4 Installing into an existing chimney ( US only ) This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable you may want to install a liner as in method Fig.27 #5 Installing into an existing fireplace chimney ( US only )
  • Page 17 Venting #6 Installing into an existing fireplace chimney ( US and Canada ) This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In Canada and some places in the US it is required that the vent pipe extend all the way to the top of the chimney.
  • Page 18 Venting Storm collar Flashing 3" min. 3" min. 3" min. PL vent manufacturer's No insulation or Minimum flue vent firestop spacer and support other combustible configuration materials allowed within 3" It is recommended that of the PL vent pipe. outside air be installed with this venting configuration.
  • Page 19 Venting Requirements for Terminating the Venting I. The clearance to service regulator vent outlet WARNING: Venting terminals must not be recessed must be a minimum of 6 feet. into a wall or siding. J. The clearance to a non-mechanical air supply NOTE: Only PL vent pipe wall pass-throughs and inlet to the building or the combustion air inlet to any fire stops should be used when venting through com-...
  • Page 20: Maintenance

    Maintenance - Cleaning Glass on View Door The unit should be out and cool to clean the door glass. It may not always be possible to allow the unit to cool off before cleaning. Therefore, if the unit is turned to the lowest setting about 1 hour before cleaning, it will make it possible to clean the glass with the unit in operation.
  • Page 21 MAINTENANCE - CLEANING 4. Remove the two heat exchanger covers. See Fig. 36. These covers are made of cast iron and are held into place with a swing latch in the upper right and left corners. See Fig 35. Swing the latch upward far enough to release the top edge of the heat exchanger cover.
  • Page 22 MAINTENANCE - CLEANING Cleaning Cont'd 5. Remove the combustion intake assembly. See Fig. 36. The combustion intake assembly is held into place with two swing latches. See Fig. 37. Swing each latch until it hangs down away from the retainer stud. Now the assembly can be taken out by tilting the right side outward first through the lower door opening.
  • Page 23 Maintenance - Burn Pot Burn Pot Cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot down to auger tube.(Fig 39) It is not necessary to completely remove all material from the burn pot. The excess will be pushed out during the next use.
  • Page 25: Trouble-Shooting

    4. The holes in the burnpot may be getting filled with all others at 3% or more. ash or carbon buildup. The Accentra is capable of burning all 3 categories of 5. Combustion blower fan blades may need cleaned. pellets due to a patented feeder and burn pot system.
  • Page 26: Specifications

    Specifications Weight 350 lbs. Blower 150 cfm Hopper Capacity 50 lbs. Fuel Wood Pellets Outside Air Size 2 3/8 inches Fuse Rating 5 amp BTU Range 0 to 40,000 Feed Rate .75 lbs./hr. on minimum(on maintenance) 5 lbs./ hr. on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage...
  • Page 27: Wiring Diagram

    Accentra Wiring Diagram...
  • Page 28: Feeder Parts

    Accentra Feeder Parts...
  • Page 29: Parts List

    Accentra Parts List Description Part Number Hopper Lid Gasket 3-44-247101 Ignitor Element Assembly 1-10-06620 Wiring Harness 3-20-08727 Burn Pot Weldment 1-10-08736 Right Feeder Shield w/sound proof 1-10-247142 Left Feeder Shield w/sound proof 1-10-247141 Heat Exchanger Cover (2) 3-00-247105 Arrow Scraper...
  • Page 30: Warranty

    MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, dealer, or other person is authorized to give any warranty on behalf of Harman Stove Company. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman Stove Company and its agents assume no liability for “resultant damages of any kind”...