Harman Stove Company Accentra Owner's Manual page 13

Cast iron pellet stove
Table of Contents

Advertisement

Room Sensor and Rear Shield Installation
Room Sensor Installation
Fig. 19
The room sensor is a small temperature sensor on
the end of a 60" gray wire. This sensor is installed much
like a standard wall thermostat. Because it is so small, it
can be hidden along the trim of a doorway or even up
the leg of a coffee table. There is a remote room sensor
port on the rear of the unit for easy external connection.
Use standard 18-2 thermostat wire to extend the dis-
tance to the desired location (100' maximum). The room
sensor should be installed in the location where you want
to control the temperature.
NOTE: Distances of more than 25 feet from the
unit or in another room are not recommended. The room
sensor is essential for the Accentra's excellent efficiency.
It is recommended that the room sensor be
installed, even if only installed on the rear of the unit as
a return air sensor. There is an intake screen on the bot-
tom of the rear sheetmetal enclosure. This is an ideal
place to tyrap the sensor head to sense return air tem-
perature.
Rear Shields
5/16" Hex Head
Screws (2 on
each side)
The rear isolated shields are split in the middle for easy
removal. Each shield has two 5/16" hex head screws
that only need to be loosened (NOT REMOVED) to
allow the shield to slide away from the unit. NOTE: It
is not recommended that the unit be operated with
the shields removed, due to the hot and moving
parts which they protect.
REMINDERS
Do not allow pellets or sawdust to build up on the
hopper lip.
Inspect the hopper lid gasket for damage. A good
hopper lid seal is very important for proper operation.
5/16" Hex Head
Screws (2 on
each side)
Fig. 20
Hopper Lid
Foam Gaskets
Hopper lip
Fig. 21