6. Tighten the nuts and bolts to secure the fuse, and then replace the cover of the
fuse holder.
7. The unit is now ready to use.
9.
MAINTENANCE INSTRUCTIONS FOR THE BOOSTER
9.1
Unplug the charger from the booster before attempting any maintenance or cleaning.
9.2
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery clamps,
9.3
Ensure that all of the booster components are in place and in good working condition.
9.4
10.
MOVING AND STORAGE INSTRUCTIONS FOR THE BOOSTER
10.1
Store the booster in an upright position, inside, in a cool, dry place.
10.2
Always make sure the booster is fully charged before storing. When not using it for long
periods of time, recharge the booster every 30 days.
IMPORTANT
damage could occur if the internal battery should unexpectedly leak acid.
11.
TROUBLESHOOTING – FOR THE BOOSTER
PROBLEM
The booster won't jump start
my car.
The booster won't power my
12V device.
The battery in the booster
won't hold a charge.
Booster shows 100% charge,
but charger still shows
charging (yellow LED).
Do not use and/or store the booster in or on any area or surface where
POSSIBLE CAUSE
Clamps are not making a good
connection to the battery.
The booster battery is not
charged.
The vehicle's battery is
defective.
The fuse has blown.
The 12V device is not turned
on.
The booster battery is not
charged.
The 12V device draws more
than 15A or has a short
circuit.
The battery is bad (will not
accept a charge).
Unit needs more charge.
Check for poor connection to
battery and frame. Make sure
connection points are clean.
Rock clamps back and forth
for a better connection.
Check the battery charge
status by pressing the button
on the front of the booster.
See LED Indicators section of
this manual.
Have the battery checked.
Replace the fuse.
(See Section 8).
Turn on the 12V device.
Check the battery charge
status by pressing the button
on the front of the booster.
See LED Indicators section of
this manual.
Disconnect the 12V device.
The internal breaker will
automatically reset after a
minute or two. Try the 12V
device again. If it happens
again, replace the 12V device.
Have the battery checked.
Charge Booster until
the charger's green LED
comes on.
6